Charcot-Marie-Tooth type 1A is caused by a 1.5 Mb DNA duplication in the 17p12 chromosomal region encompassing the peripheral myelin protein 22 gene. In the present study, we compared the Real-Time PCR with the other methods currently used for the diagnosis of Charcot-Marie-Tooth. By using a combination of junction fragment PCR, analysis of microsatellite markers, and pulsed field gel electrophoresis, we identified 76 unrelated patients with 17p12 duplication. In these patients, junction fragment PCR detected 63% of cases of duplication, the microsatellite markers method revealed 74%, while the combined use of microsatellite markers and junction fragment PCR revealed 91% of cases of Charcot-Marie-Tooth type 1A. Pulsed field gel electrophoresis detected 100% of the cases with duplication, even in presence of atypical 17p12 duplication. Real-Time PCR detected 100% of the cases with Charcot-Marie-Tooth type 1A and was comparable to pulsed field gel electrophoresis. However, in contrast to pulsed field gel electrophoresis, Real-Time PCR does not need fresh blood, minimizes diagnosis time and cost, and thus can be easily used for the molecular diagnosis of Charcot-Marie-Tooth type 1A.

Comparison of different techniques for detecting 17p12 duplication in CMT1A.

RODOLICO, Carmelo;MAZZEO, Anna;TOSCANO, Antonio;VITA, Giuseppe;
2005-01-01

Abstract

Charcot-Marie-Tooth type 1A is caused by a 1.5 Mb DNA duplication in the 17p12 chromosomal region encompassing the peripheral myelin protein 22 gene. In the present study, we compared the Real-Time PCR with the other methods currently used for the diagnosis of Charcot-Marie-Tooth. By using a combination of junction fragment PCR, analysis of microsatellite markers, and pulsed field gel electrophoresis, we identified 76 unrelated patients with 17p12 duplication. In these patients, junction fragment PCR detected 63% of cases of duplication, the microsatellite markers method revealed 74%, while the combined use of microsatellite markers and junction fragment PCR revealed 91% of cases of Charcot-Marie-Tooth type 1A. Pulsed field gel electrophoresis detected 100% of the cases with duplication, even in presence of atypical 17p12 duplication. Real-Time PCR detected 100% of the cases with Charcot-Marie-Tooth type 1A and was comparable to pulsed field gel electrophoresis. However, in contrast to pulsed field gel electrophoresis, Real-Time PCR does not need fresh blood, minimizes diagnosis time and cost, and thus can be easily used for the molecular diagnosis of Charcot-Marie-Tooth type 1A.
2005
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1718848
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact