A comprehensive two-dimensional gas chromatography (GC x GC) system (for convenience defined as "split flow" GC x GC), which may be operated at improved gas linear velocities in both dimensions, has been developed. The setup is formed of an apolar 30 m x 0.25 mm i.d. column connected, by means of a Y press fit, to a detector-linked 1 m x 0.1 mm i.d. polar analytical column, which passes through the (cryogenic) modulator, and to a 0.3 m x 0.1 mm i.d. retention gap, which is connected to a manually operated split valve. The latter enables the regulation of gas flows through the second analytical column [e.g., 60:40 (FID) ratio, 50:50 ratio, 40:60 (FID) ratio, etc.], in order to generate the most appropriate gas linear velocity, which is related to each specific analysis. In the pre-sent investigation, two sets of traditional and split flow GC x GC analyses were carried out on a cod liver oil fatty acid methyl ester sample by using the same temperature programs [180-250 degrees C at (a) 3 degrees C/min and at (b) 1.3 degrees C/min] and at an average first-dimension linear velocity of similar to 35.0 cm/s; thus, primary column retention times (and therefore elution temperatures) were essentially maintained. The second-dimension linear velocity was calculated to be similar to 333 cm/s in the traditional applications, while it was split valve-regulated until the most appropriate values [(a) similar to 213 cm/s; (b) similar to 264 cm/s] were attained in the alternative applications. Substantial improvements were observed and measured in the chromatography along the y-axis, while the contour plot chemical class structure was maintained.

Generation of improved gas linear velocities in a comprehensive two-dimensional gas chromatography system

TRANCHIDA, Peter Quinto;DUGO, Paola;DUGO, Giovanni;MONDELLO, Luigi
2007-01-01

Abstract

A comprehensive two-dimensional gas chromatography (GC x GC) system (for convenience defined as "split flow" GC x GC), which may be operated at improved gas linear velocities in both dimensions, has been developed. The setup is formed of an apolar 30 m x 0.25 mm i.d. column connected, by means of a Y press fit, to a detector-linked 1 m x 0.1 mm i.d. polar analytical column, which passes through the (cryogenic) modulator, and to a 0.3 m x 0.1 mm i.d. retention gap, which is connected to a manually operated split valve. The latter enables the regulation of gas flows through the second analytical column [e.g., 60:40 (FID) ratio, 50:50 ratio, 40:60 (FID) ratio, etc.], in order to generate the most appropriate gas linear velocity, which is related to each specific analysis. In the pre-sent investigation, two sets of traditional and split flow GC x GC analyses were carried out on a cod liver oil fatty acid methyl ester sample by using the same temperature programs [180-250 degrees C at (a) 3 degrees C/min and at (b) 1.3 degrees C/min] and at an average first-dimension linear velocity of similar to 35.0 cm/s; thus, primary column retention times (and therefore elution temperatures) were essentially maintained. The second-dimension linear velocity was calculated to be similar to 333 cm/s in the traditional applications, while it was split valve-regulated until the most appropriate values [(a) similar to 213 cm/s; (b) similar to 264 cm/s] were attained in the alternative applications. Substantial improvements were observed and measured in the chromatography along the y-axis, while the contour plot chemical class structure was maintained.
2007
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1730492
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 47
social impact