This paper reports a fast and accurate RP-HPLC chromatographic method for the simultaneous determination of 3-hydroxyflavone (3-OHF) and its photodegradation products. Solutions (5 × 10−5 M) in acetonitrile (ACN) of the molecule were subjected to forced degradation by exposure to artificial UV-A light source (black-light, λmax 354 nm) and the changes appearing in chromatograms were monitored at selected irradiation times. A multistep gradient was optimised to achieve complete elution of all photoproducts in the shortest analysis time. UV spectra recorded by the diode array detector system (285 and 340 nm) clearly showed the structural changes in the new species formed, with respect to the parent compound. The analytical method was subjected to a validation procedure in which linearity and range, as well as specificity, precision and accuracy were determined according to ICH guidelines. Quantitative evaluation of the photochemical process was performed on the basis of the calculated kinetic parameters: photodegradation rate constant k, half-life time t0.5, time degradation of 10% of the drug t0.1.

Selective reversed-phase liquid chromatography method for the kinetic investigation of 3-hydroxyflavone photostability

CALABRO', Maria;TOMMASINI, Silvana;RANERI, Daniela;DONATO, Paola Agata Eustochia;FICARRA, Paola;FICARRA, Rita
2004-01-01

Abstract

This paper reports a fast and accurate RP-HPLC chromatographic method for the simultaneous determination of 3-hydroxyflavone (3-OHF) and its photodegradation products. Solutions (5 × 10−5 M) in acetonitrile (ACN) of the molecule were subjected to forced degradation by exposure to artificial UV-A light source (black-light, λmax 354 nm) and the changes appearing in chromatograms were monitored at selected irradiation times. A multistep gradient was optimised to achieve complete elution of all photoproducts in the shortest analysis time. UV spectra recorded by the diode array detector system (285 and 340 nm) clearly showed the structural changes in the new species formed, with respect to the parent compound. The analytical method was subjected to a validation procedure in which linearity and range, as well as specificity, precision and accuracy were determined according to ICH guidelines. Quantitative evaluation of the photochemical process was performed on the basis of the calculated kinetic parameters: photodegradation rate constant k, half-life time t0.5, time degradation of 10% of the drug t0.1.
2004
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1888512
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact