PURPOSE: To evaluate the accuracy of MR pyelography in the assessment of hydroureteronephrosis. MATERIAL AND METHODS: One hundred and fifteen patients, with variable degree of hydroureteronephrosis demonstrated by US and urography were subjected to MR pyelography obtained by means of two ultra-fast sequences. RESULTS: Of the 228 kidneys examined, the collecting systems of 130 kidneys were dilated and correctly identified on MR pyelography, with only 2 false-positive results. The specificity of MR pyelography in detecting hydronephrosis was 98%. Accuracy in revealing level of obstruction was 100%. Sensitivity in detecting stones, strictures and congenital ureteropelvic junction obstructions was respectively 68.9%, 98.5% and 100%. CONCLUSION: MR pyelography can rapidly and accurately depict the morphological features of dilated urinary tracts with information regarding the degree and level of obstruction, without using contrast medium or ionizing radiation.

MR pyelography in 115 patients with a dilated renal collecting system

BLANDINO, Alfredo;GAETA, Michele;MINUTOLI, Fabio;SCRIBANO, Emanuele;VINCI, Sergio Lucio;FAMULARI, Ciro;PANDOLFO, Ignazio
2001-01-01

Abstract

PURPOSE: To evaluate the accuracy of MR pyelography in the assessment of hydroureteronephrosis. MATERIAL AND METHODS: One hundred and fifteen patients, with variable degree of hydroureteronephrosis demonstrated by US and urography were subjected to MR pyelography obtained by means of two ultra-fast sequences. RESULTS: Of the 228 kidneys examined, the collecting systems of 130 kidneys were dilated and correctly identified on MR pyelography, with only 2 false-positive results. The specificity of MR pyelography in detecting hydronephrosis was 98%. Accuracy in revealing level of obstruction was 100%. Sensitivity in detecting stones, strictures and congenital ureteropelvic junction obstructions was respectively 68.9%, 98.5% and 100%. CONCLUSION: MR pyelography can rapidly and accurately depict the morphological features of dilated urinary tracts with information regarding the degree and level of obstruction, without using contrast medium or ionizing radiation.
2001
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1892073
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 15
social impact