The authors report their experience in the reconstruction of the anterior cruciate ligament using the Leeds-Keio ligament in 12 patients, 7 by open arthrotomy and 5 by an arthroscopic technique. The biological evolution of the new ligament was studied macroscopically and histologically in the first 6 cases treated by open arthrotomy. Arthroscopic monitoring and biopsy was carried out 4 to 10 months after operation. In 5 cases the new ligament appeared to be intact and histologically vital, with proliferation of new tissue along the new ligament. There were broken filaments of dacron hanging from the intercondylar cavity in only one case. The first macroscopic, histological and ultrastructural results show that despite a few limitations the Leeds-Keio ligament has the features required for replacement of the anterior cruciate ligament, although it will be necessary to wait 4 or 5 years before fully evaluating the durability and function of the ligament and the best operative method.

The biological evolution of the Leeds-Keio ligament in the human knee. A histological and ultrastructural study.

PUZZOLO, Domenico;PISANI, Antonina Maria;
1988-01-01

Abstract

The authors report their experience in the reconstruction of the anterior cruciate ligament using the Leeds-Keio ligament in 12 patients, 7 by open arthrotomy and 5 by an arthroscopic technique. The biological evolution of the new ligament was studied macroscopically and histologically in the first 6 cases treated by open arthrotomy. Arthroscopic monitoring and biopsy was carried out 4 to 10 months after operation. In 5 cases the new ligament appeared to be intact and histologically vital, with proliferation of new tissue along the new ligament. There were broken filaments of dacron hanging from the intercondylar cavity in only one case. The first macroscopic, histological and ultrastructural results show that despite a few limitations the Leeds-Keio ligament has the features required for replacement of the anterior cruciate ligament, although it will be necessary to wait 4 or 5 years before fully evaluating the durability and function of the ligament and the best operative method.
1988
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/2214870
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact