The present research is based on the development and use of a flow-modulation (FM) comprehensive two-dimensional gas chromatography-quadrupole mass spectrometry (GC × GC-qMS) method for the determination of recently-highlighted (by the Scientific Committee on Consumer Safety) fragrance allergens (54) in cosmetics. FM GC × GC-qMS conditions were finely tuned to generate flow conditions (≈7 mL min-1) compatible with the qMS system used. Six-point calibration curves, over the range 1, 5, 10, 20, 50, 100 mg L-1, were constructed for the 54 target allergens, with satisfactory linearity observed in all cases. Absolute quantification was performed by using extracted ions; target analyte identification was performed through measurement of ion ratios (qualifier/quantifier), full-scan MS database matching and the use of linear retention indices. Additional analytical figures of merit subjected to measurement were intra-day repeatability, accuracy at the 25 and 5 mg L-1 levels, and limits of detection and quantification. The number of data points per peak, along with mass spectral skewing, was also subjected to evaluation. Finally, the FM GC × GC-qMS method was used not only for the quantification of target allergens in five commercial perfumes, but also for general qualitative profiling.

Four-stage (low-)flow modulation comprehensive gas chromatography-quadrupole mass spectrometry for the determination of recently-highlighted cosmetic allergens

TRANCHIDA, Peter Quinto
Primo
;
MAIMONE, MARIAROSA
Secondo
;
FRANCHINA, FLAVIO ANTONIO;MONDELLO, Luigi
Ultimo
2016-01-01

Abstract

The present research is based on the development and use of a flow-modulation (FM) comprehensive two-dimensional gas chromatography-quadrupole mass spectrometry (GC × GC-qMS) method for the determination of recently-highlighted (by the Scientific Committee on Consumer Safety) fragrance allergens (54) in cosmetics. FM GC × GC-qMS conditions were finely tuned to generate flow conditions (≈7 mL min-1) compatible with the qMS system used. Six-point calibration curves, over the range 1, 5, 10, 20, 50, 100 mg L-1, were constructed for the 54 target allergens, with satisfactory linearity observed in all cases. Absolute quantification was performed by using extracted ions; target analyte identification was performed through measurement of ion ratios (qualifier/quantifier), full-scan MS database matching and the use of linear retention indices. Additional analytical figures of merit subjected to measurement were intra-day repeatability, accuracy at the 25 and 5 mg L-1 levels, and limits of detection and quantification. The number of data points per peak, along with mass spectral skewing, was also subjected to evaluation. Finally, the FM GC × GC-qMS method was used not only for the quantification of target allergens in five commercial perfumes, but also for general qualitative profiling.
2016
File in questo prodotto:
File Dimensione Formato  
416 paper 12-16.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.12 MB
Formato Adobe PDF
1.12 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3091091
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 28
social impact