AIM: To evaluate the efficacy and safety of the excimer laser correction of the residual refractive errors after cataract extraction with intraocular lens (IOL) implantation in uncommon cases. METHODS: Totally 24 patients with high residual refractive error after cataract surgery with IOL implantation were examined. Twenty-two patients had a history of phacoemulsification and IOL implantation, and two had extra-capsular cataract extraction with IOL implantation. Detailed examination of preoperative medical records was done to explain the origin of the post-cataract refractive errors. All patients underwent photorefractire keratectomy (PRK) enhancement. The mean outcome measures were refraction, uncorretted visual acuity (UCVA), best corrected visual acuity (BCVA) and corneal transparency and follow up ranged from 1 to 8y. RESULTS: The principal causes of residual ametropia was inexact IOL calculation in abnormal eyes with high myopia and congenital lens abnormalities, followed by corneal astigmatism both suture induced and preexisting. After cataract surgery and before the laser enhancement the mean spherical equivalent (SE) was -0.56±3 D ranging from -4.62 to +2.25 D in high myopic patients, instead it was -1±1.73 D ranging from -3.25 to +3.75 D in the astigmatic eyes, with a mean cylinder of -3.75±0 ranging from -3 to +5.50 D. After laser refractive surgery the mean SE was 0.1±0.73, ranging from -0.50 to +1.50 in the myopic group, and it was -0.50±0.57 ranging from -1.25 to +0.50 in astigmatic patients, with a mean cylinder of -0.25±0.75. In myopic patients the mean UCVA and BCVA were 0.038±0.072 logMAR and 0.018±0.04 respectively, both ranging from 0.10 to 0.0. In astigmatic patients, the mean UCVA and BCVA were 0.213±0.132 and 0.00±0.0 respectively, UCVA ranging from 0.50 to 0.22 and BCVA was 0.00. All patients presented normal corneal transparency. No ocular hypertension was detected and no corneal haze was observed. All registered values remained stable also at the end line evaluation. CONCLUSION: The excimer laser treatment of residual refractive errors after cataract surgery with IOL implantation in abnormal eyes resulted in satisfactory and stable visual outcome with good safety and efficacy.

Photorefractive keratectomy after cataract surgery in uncommon cases: long-term results

Roszkowska, Anna Maria
Primo
;
Aragona, Pasquale
Ultimo
2018-01-01

Abstract

AIM: To evaluate the efficacy and safety of the excimer laser correction of the residual refractive errors after cataract extraction with intraocular lens (IOL) implantation in uncommon cases. METHODS: Totally 24 patients with high residual refractive error after cataract surgery with IOL implantation were examined. Twenty-two patients had a history of phacoemulsification and IOL implantation, and two had extra-capsular cataract extraction with IOL implantation. Detailed examination of preoperative medical records was done to explain the origin of the post-cataract refractive errors. All patients underwent photorefractire keratectomy (PRK) enhancement. The mean outcome measures were refraction, uncorretted visual acuity (UCVA), best corrected visual acuity (BCVA) and corneal transparency and follow up ranged from 1 to 8y. RESULTS: The principal causes of residual ametropia was inexact IOL calculation in abnormal eyes with high myopia and congenital lens abnormalities, followed by corneal astigmatism both suture induced and preexisting. After cataract surgery and before the laser enhancement the mean spherical equivalent (SE) was -0.56±3 D ranging from -4.62 to +2.25 D in high myopic patients, instead it was -1±1.73 D ranging from -3.25 to +3.75 D in the astigmatic eyes, with a mean cylinder of -3.75±0 ranging from -3 to +5.50 D. After laser refractive surgery the mean SE was 0.1±0.73, ranging from -0.50 to +1.50 in the myopic group, and it was -0.50±0.57 ranging from -1.25 to +0.50 in astigmatic patients, with a mean cylinder of -0.25±0.75. In myopic patients the mean UCVA and BCVA were 0.038±0.072 logMAR and 0.018±0.04 respectively, both ranging from 0.10 to 0.0. In astigmatic patients, the mean UCVA and BCVA were 0.213±0.132 and 0.00±0.0 respectively, UCVA ranging from 0.50 to 0.22 and BCVA was 0.00. All patients presented normal corneal transparency. No ocular hypertension was detected and no corneal haze was observed. All registered values remained stable also at the end line evaluation. CONCLUSION: The excimer laser treatment of residual refractive errors after cataract surgery with IOL implantation in abnormal eyes resulted in satisfactory and stable visual outcome with good safety and efficacy.
File in questo prodotto:
File Dimensione Formato  
International Journal Ophthalmology. PRK after cataract in uncommon cases. 2018.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 251.65 kB
Formato Adobe PDF
251.65 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3126201
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 7
social impact