Considering the diagnostic capability offered by cone-beam computed tomography (CBCT), nowadays orthodontists often use this exam for treatment planning, especially in cases of impacted teeth, maxillary ipoplasia, orthognatic surgery etc. The aim of this study was to compare the radiation doses related to a conventional CBCT setting and that of a low dose protocol, usable in orthodontic practice. The absorbed organ doses were measured using an anthropomorphic phantom loaded with thermoluminescent dosimeters related to sensitive organs (brain, bone marrow, salivary glands, thyroid, esophagus, oral mucosa, extrathoracic airways, lymph nodes). The device used was a MyRay Hyperion X9-11x5. The standard setting of the apparatus was 90 Kv, 36 mAs, CTDI/Vol 4.09 mGy, instead the low dose one was 90 Kv, 27 mAs, CTDI/Vol 2.89 mGy. Equivalent and effective doses have been calculated; the measurement of the effective doses was based on the ICRP recommendations. For the assessment of image quality, five readers, independent and experienced orthodontists, were asked to state if the images were sufficient enough to perform an orthodontic diagnosis. The lowest organ dose (5.01 microSv) was received by the esophagus during low dose CBCT acquisition. The highest mean organ dose instead (1227,67 microSv) was received by the salivary glands during conventional setting CBCT acquisition. Image quality has been considered sufficient for orthodontic diagnostic needs for both CBCT protocols. CBCT low dose setting should be preferred over the standard one in orthodontic practice, because provide a significant lower radiation dose to the patients ensuring a good image quality. However, further studies are necessary to evaluate the opportunity of CBCT exams in orthodontic treatment planning.

Standard and Low-Dose cone beam computer tomography protocol for orthognatodonic diagnosis: a comparative evaluation

M. PORTELLI
Primo
;
A. MILITI
Methodology
;
A. LO GIUDICE
Methodology
;
R. LO GIUDICE
Methodology
;
R. FASTUCA
Formal Analysis
;
I. IELO
Formal Analysis
;
G. LO GIUDICE
Software
;
R. NUCERA
Ultimo
Data Curation
2018-01-01

Abstract

Considering the diagnostic capability offered by cone-beam computed tomography (CBCT), nowadays orthodontists often use this exam for treatment planning, especially in cases of impacted teeth, maxillary ipoplasia, orthognatic surgery etc. The aim of this study was to compare the radiation doses related to a conventional CBCT setting and that of a low dose protocol, usable in orthodontic practice. The absorbed organ doses were measured using an anthropomorphic phantom loaded with thermoluminescent dosimeters related to sensitive organs (brain, bone marrow, salivary glands, thyroid, esophagus, oral mucosa, extrathoracic airways, lymph nodes). The device used was a MyRay Hyperion X9-11x5. The standard setting of the apparatus was 90 Kv, 36 mAs, CTDI/Vol 4.09 mGy, instead the low dose one was 90 Kv, 27 mAs, CTDI/Vol 2.89 mGy. Equivalent and effective doses have been calculated; the measurement of the effective doses was based on the ICRP recommendations. For the assessment of image quality, five readers, independent and experienced orthodontists, were asked to state if the images were sufficient enough to perform an orthodontic diagnosis. The lowest organ dose (5.01 microSv) was received by the esophagus during low dose CBCT acquisition. The highest mean organ dose instead (1227,67 microSv) was received by the salivary glands during conventional setting CBCT acquisition. Image quality has been considered sufficient for orthodontic diagnostic needs for both CBCT protocols. CBCT low dose setting should be preferred over the standard one in orthodontic practice, because provide a significant lower radiation dose to the patients ensuring a good image quality. However, further studies are necessary to evaluate the opportunity of CBCT exams in orthodontic treatment planning.
2018
File in questo prodotto:
File Dimensione Formato  
Nucera_STANDARD AND LOWDOSE CONE BEAM COMPUTER TOMOGRAPHY.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 575.64 kB
Formato Adobe PDF
575.64 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3126954
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 15
  • ???jsp.display-item.citation.isi??? ND
social impact