Focusing on the interplay between interface chemistry, electrochemistry, and integrated electronics, we show a novel low-cost and flexible biosensing platform for continuous glucose monitoring. The amperometric biosensing system features a planar three-electrode structure on a plastic substrate, and a wireless near-field communication-powered electronic system performing sensor analog front-end, A/D conversion, digital control, and display tasks. The working electrode is made of electropolymerized poly (3,4-ethylenedioxythiophene) film onto a polyethylene terephthalate/gold electrode followed by immobilization of cross-linked glucose oxidase by glutaraldehyde. The advantages offered by such a device, including low-cost materials and instrumentation as well as the good sensitivity of 9.24 mu ext{A}/({mathrm {mM}} cdot {mathrm {cm}}^{2}) are promising tools for point-of-care monitoring. It is demonstrated that the devices are good candidates for the development of advanced sensing approaches based on the investigation of the noise produced during operation (fluctuation-enhanced sensing).

Amperometric Biosensor and Front-End Electronics for Remote Glucose Monitoring by Crosslinked PEDOT-Glucose Oxidase

Scandurra, Graziella;Cannata, Gianluca;Giusi, Gino;Ciofi, Carmine;
2018-01-01

Abstract

Focusing on the interplay between interface chemistry, electrochemistry, and integrated electronics, we show a novel low-cost and flexible biosensing platform for continuous glucose monitoring. The amperometric biosensing system features a planar three-electrode structure on a plastic substrate, and a wireless near-field communication-powered electronic system performing sensor analog front-end, A/D conversion, digital control, and display tasks. The working electrode is made of electropolymerized poly (3,4-ethylenedioxythiophene) film onto a polyethylene terephthalate/gold electrode followed by immobilization of cross-linked glucose oxidase by glutaraldehyde. The advantages offered by such a device, including low-cost materials and instrumentation as well as the good sensitivity of 9.24 mu ext{A}/({mathrm {mM}} cdot {mathrm {cm}}^{2}) are promising tools for point-of-care monitoring. It is demonstrated that the devices are good candidates for the development of advanced sensing approaches based on the investigation of the noise produced during operation (fluctuation-enhanced sensing).
2018
File in questo prodotto:
File Dimensione Formato  
sensors_J.pdf

solo gestori archivio

Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.12 MB
Formato Adobe PDF
2.12 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3134297
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 24
social impact