In this paper, a miniaturized biosensor containing 96 silicon microchambers electroloaded with nano‐volumes of liquid (EW‐chip) is presented. The liquid electroloading is achieved by the appropriate modulation of interface properties. The surface chemistries have been studied to guarantee effective interface properties for both electrowetting on dielectric actuation and biocompatibility versus biochemical reactions. The silicon microchambers are 200 nl in volume and are connected to a specific system of electrodes able to deliver liquid sample on each well. The device also integrates temperature sensors and heaters to perform biochemical reactions. On that, the effectiveness of this device has been successfully proven towards the nucleic acids detection via real‐time polymerase chain reaction amplification. Hepatitis B virus genome target has been used to assess the device performance. Results show very uniform amplification over the 96 microchambers without any cross‐contamination process. These features make this system a very appealing potential solution for genetic point‐of‐care devices where a high level of parallelism of analysis is required.

EWOD silicon biosensor for multiple nucleic acids analysis

Conoci S.
Ultimo
2019-01-01

Abstract

In this paper, a miniaturized biosensor containing 96 silicon microchambers electroloaded with nano‐volumes of liquid (EW‐chip) is presented. The liquid electroloading is achieved by the appropriate modulation of interface properties. The surface chemistries have been studied to guarantee effective interface properties for both electrowetting on dielectric actuation and biocompatibility versus biochemical reactions. The silicon microchambers are 200 nl in volume and are connected to a specific system of electrodes able to deliver liquid sample on each well. The device also integrates temperature sensors and heaters to perform biochemical reactions. On that, the effectiveness of this device has been successfully proven towards the nucleic acids detection via real‐time polymerase chain reaction amplification. Hepatitis B virus genome target has been used to assess the device performance. Results show very uniform amplification over the 96 microchambers without any cross‐contamination process. These features make this system a very appealing potential solution for genetic point‐of‐care devices where a high level of parallelism of analysis is required.
2019
File in questo prodotto:
File Dimensione Formato  
3148773.pdf

solo gestori archivio

Descrizione: EWOD silicon biosensor for multiple nucleic acids analysis
Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3148773
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact