Background To report a technical complication during a chimney-thoracic endovascular aneurysm repair (Ch-TEVAR) procedure. Methods A 77-year-old female patient underwent Ch-TEVAR for a symptomatic thoracic aortic aneurysm with a short and angulated proximal neck. Deployment of the aortic stent graft over the left subclavian artery (LSA) was followed by placement of a balloon-expandable covered stent as a chimney for the LSA. Results Chimney deployment failed due to balloon perforation. Additional attempts with several balloons all failed, albeit gaining some additional expansion of the chimney stent graft. The technical complication was solved by deploying a self-expanding bare stent inside the chimney stent. This enabled additional ballooning and further expansion of the chimney stent graft leading to an acceptable end result. Conclusions Ch-TEVAR with a balloon-expandable chimney stent graft can be complicated by incomplete chimney deployment due to balloon perforation. Relining of the chimney stent graft with a self-expanding stent improved the deployment with acceptable patency.

Incomplete Expansion of Chimney Stent Graft during Chimney-Thoracic Endovascular Aneurysm Repair

Spinelli D.
Secondo
;
2017-01-01

Abstract

Background To report a technical complication during a chimney-thoracic endovascular aneurysm repair (Ch-TEVAR) procedure. Methods A 77-year-old female patient underwent Ch-TEVAR for a symptomatic thoracic aortic aneurysm with a short and angulated proximal neck. Deployment of the aortic stent graft over the left subclavian artery (LSA) was followed by placement of a balloon-expandable covered stent as a chimney for the LSA. Results Chimney deployment failed due to balloon perforation. Additional attempts with several balloons all failed, albeit gaining some additional expansion of the chimney stent graft. The technical complication was solved by deploying a self-expanding bare stent inside the chimney stent. This enabled additional ballooning and further expansion of the chimney stent graft leading to an acceptable end result. Conclusions Ch-TEVAR with a balloon-expandable chimney stent graft can be complicated by incomplete chimney deployment due to balloon perforation. Relining of the chimney stent graft with a self-expanding stent improved the deployment with acceptable patency.
2017
File in questo prodotto:
File Dimensione Formato  
15 Incomplete Expansion of Chimney Stent-Graft during Chimney-Thoracic Endovascular Aneurysm Repair (Ch-TEVAR).pdf

solo utenti autorizzati

Descrizione: Accepted Manuscript
Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 802.41 kB
Formato Adobe PDF
802.41 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Incomplete_Spinelli_2017_3176014 .pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.49 MB
Formato Adobe PDF
1.49 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3176014
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact