In any of the modern 4 pi particle detector array improvements of the measured parameters have been envisaged. Pulse Shape Discrimination (PSD) is an efficient electronic tool which can be applied to a single detector to achieve atomic number Z separation of the particles comparable to the Delta E - E telescopes. In the present study, a simple PSD device based on commercially available modules has been discussed with the motivation of future improvement in CHIMERA detector system without sacrificing time resolution in time of flight (TOF) measurement. In beam studies of PSD have been carried out following the ejected particles from F-19 + C-12 reaction at Tandem energies with 2 large area - 300 mu m- silicon detectors of CHIMERA multi-detector. Front-side and rear-side entry of the detected ions were explored. Performance of the PSD set up has been discussed.

A new electronic set up for pulse shape method with large area planar silicon detector of CHIMERA

AUDITORE, Lucrezia;TRIFIRO', ANTONIO;TRIMARCHI, MARINA;
2004-01-01

Abstract

In any of the modern 4 pi particle detector array improvements of the measured parameters have been envisaged. Pulse Shape Discrimination (PSD) is an efficient electronic tool which can be applied to a single detector to achieve atomic number Z separation of the particles comparable to the Delta E - E telescopes. In the present study, a simple PSD device based on commercially available modules has been discussed with the motivation of future improvement in CHIMERA detector system without sacrificing time resolution in time of flight (TOF) measurement. In beam studies of PSD have been carried out following the ejected particles from F-19 + C-12 reaction at Tandem energies with 2 large area - 300 mu m- silicon detectors of CHIMERA multi-detector. Front-side and rear-side entry of the detected ions were explored. Performance of the PSD set up has been discussed.
2004
Inglese
2004 IEEE Nuclear Science Symposium Conference Record
IEEE / Institute of Electrical and Electronics Engineers Incorporated:445 Hoes Lane:Piscataway, NJ 08854:(800)701-4333, (732)981-0060, EMAIL: [email protected], INTERNET: http://www.ieee.org, Fax: (732)981-9667
Piscataway, NJ
STATI UNITI D'AMERICA
no
3
1742
1746
5
0780387007
Nuclear Science Symposium/Medical Imaging Conference
Rome, ITALY
OCT 16-22, 2004
Internazionale
Sì, ma tipo non specificato
none
M., Alderighi; F., Amorini; A., Anzalone; N., Arena; Auditore, Lucrezia; R., Bassini; C., Boiano; G., Cardella; S., Cavallaro; Chatterjee, M. B.; M., ...espandi
41
14.d Contributo in Atti di Convegno::14.d.3 Contributi in extenso in Atti di convegno
273
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1994623
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact