A person moving in and around the MRI site may experience strong time-varying magnetic fields. The physical consequence of the time variation of the magnetic flux density is the induction of currents in body parts. In this paper the time-varying gradient exposure associated with the magnetic flux densities is evaluated and measured. The acquired data, obtained from a personal magnetic dosimeter, represent the magnetic flux density function, B = B(t), related to the operator movement inside the MRI site. Such data have been processed to evaluate the corresponding dB/dt curves, that were estimated by calculating the time derivative. All the measurements were conducted on a 3.0 T MRI site, dedicated to research procedures, in two different conditions: at first during routine patient positioning, and secondly, simulating an emergency. In both the measurement conditions, two dosime-ters, with different acquisition times, were simultaneously used. They were positioned the first time on the operator’s torso and the second one on his head. The analysis conducted, simulating both normal and emergency conditions, demon-strated that the dB/dt peak values strictly depended on human motion through strong static magnetic fields, and, sometimes, exceeded the recommended limit. This consequence highlighted the necessity of drawing up, as in case of ionizing radiation, behavioral rules to be followed by workers and patients. Therefore it will be necessary to assess risk conditions in a proper manner.

Personal Time-Varying Magnetic Fields Evaluation During Activities in MRI Sites

ACRI, Giuseppe;TESTAGROSSA, Barbara;VERMIGLIO, Giuseppe
2015-01-01

Abstract

A person moving in and around the MRI site may experience strong time-varying magnetic fields. The physical consequence of the time variation of the magnetic flux density is the induction of currents in body parts. In this paper the time-varying gradient exposure associated with the magnetic flux densities is evaluated and measured. The acquired data, obtained from a personal magnetic dosimeter, represent the magnetic flux density function, B = B(t), related to the operator movement inside the MRI site. Such data have been processed to evaluate the corresponding dB/dt curves, that were estimated by calculating the time derivative. All the measurements were conducted on a 3.0 T MRI site, dedicated to research procedures, in two different conditions: at first during routine patient positioning, and secondly, simulating an emergency. In both the measurement conditions, two dosime-ters, with different acquisition times, were simultaneously used. They were positioned the first time on the operator’s torso and the second one on his head. The analysis conducted, simulating both normal and emergency conditions, demon-strated that the dB/dt peak values strictly depended on human motion through strong static magnetic fields, and, sometimes, exceeded the recommended limit. This consequence highlighted the necessity of drawing up, as in case of ionizing radiation, behavioral rules to be followed by workers and patients. Therefore it will be necessary to assess risk conditions in a proper manner.
2015
978-3-319-19386-1
978-3-319-19387-8
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3060556
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact