An over-voltage mitigation technique for open-end winding electrical drives with long power cables is proposed in this paper. In particular, a suitable dwell time is included in the switching patterns of the two inverters to minimize the over-voltage occurring at the stator terminals of this kind of systems. No passive RLC networks are required, thus avoiding additional costs and extra power losses. The proposed approach is first theoretically introduced, then validated by numerical simulations and experimental tests. Finally its effectiveness is compared with that of conventional passive RC filters.

Overvoltage mitigation in open-end winding AC motor drives

FOTI, SALVATORE;TESTA, Antonio;DE CARO, SALVATORE;SCIMONE, Tommaso
2015-01-01

Abstract

An over-voltage mitigation technique for open-end winding electrical drives with long power cables is proposed in this paper. In particular, a suitable dwell time is included in the switching patterns of the two inverters to minimize the over-voltage occurring at the stator terminals of this kind of systems. No passive RLC networks are required, thus avoiding additional costs and extra power losses. The proposed approach is first theoretically introduced, then validated by numerical simulations and experimental tests. Finally its effectiveness is compared with that of conventional passive RC filters.
2015
9781479999828
9781479999828
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3083501
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact