The technological implementation of STT-magnetic random-access memory (MRAM) in real devices needs a complete description of the statistical switching behavior at room temperature. In this paper, we investigate, by means of a full micromagnetic model, the effect of the interfacial Dzyaloshinskii-Moriya interaction (IDMI) on the critical current density and probability density function (PDF) of the switching time in perpendicular STT-MRAMs. We show that for large enough values of the symmetric exchange interaction, the negative effect of the IDMI on the critical current is strongly reduced. In addition, a comprehensive analysis of the four main statistical moments (mean, standard deviation, skewness, and kurtosis) points out that to fit the switching time PDF in order to maintain a quadratic error at least one order of magnitude smaller than skew normal PDF, a Pearson type IV PDF has to be used also in presence of the IDMI.
Micromagnetic analysis of statistical switching in perpendicular STT-MRAM with interfacial Dzyaloshinskii–Moriya Interaction
SIRACUSANO, GIULIO
Primo
;PULIAFITO, VITO;GIORDANO, ANNA;AZZERBONI, Bruno;LA CORTE, Aurelio;FINOCCHIO, GiovanniPenultimo
;
2017-01-01
Abstract
The technological implementation of STT-magnetic random-access memory (MRAM) in real devices needs a complete description of the statistical switching behavior at room temperature. In this paper, we investigate, by means of a full micromagnetic model, the effect of the interfacial Dzyaloshinskii-Moriya interaction (IDMI) on the critical current density and probability density function (PDF) of the switching time in perpendicular STT-MRAMs. We show that for large enough values of the symmetric exchange interaction, the negative effect of the IDMI on the critical current is strongly reduced. In addition, a comprehensive analysis of the four main statistical moments (mean, standard deviation, skewness, and kurtosis) points out that to fit the switching time PDF in order to maintain a quadratic error at least one order of magnitude smaller than skew normal PDF, a Pearson type IV PDF has to be used also in presence of the IDMI.File | Dimensione | Formato | |
---|---|---|---|
127RI-Micromagnetic analysis of statistical switching.pdf
solo utenti autorizzati
Descrizione: 127RI-Micromagnetic analysis of statistical switching
Tipologia:
Versione Editoriale (PDF)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.07 MB
Formato
Adobe PDF
|
1.07 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.