The present paper deals with a study of an air turbine as power take-off in Oscillating Water Column systems. In Particular, the focus of the study is on the analysis of the air turbine performance in ducted configuration. Savonius type turbines were tested as a function of air flux oscillation frequency. In more details, a turbine with an overlap ratio of 1/6 was used, while three air flux oscillating frequencies are imposed: 0.1, 0.5, 1 and 1.5?Hz. In order to measure turbine performance, a specific experimental setup was built, based on an OWC simulator. The testing tube (operating as power take-off simulator) was built using transparent materials to allow Particle Image Velocimetry measurement. A simple band brake system was used to apply load to turbine shaft and to measure turbine torque. Therefore, turbine torque, rotational speed, pressure drop and input air velocity were registered and turbine power and power coefficient as a function of tip speed ratio were calculated.

Vertical axis air turbine in oscillating water column systems

Brusca S.
Primo
;
Famoso F.
Secondo
;
Galvagno A.;Prestipino M.
Ultimo
2019-01-01

Abstract

The present paper deals with a study of an air turbine as power take-off in Oscillating Water Column systems. In Particular, the focus of the study is on the analysis of the air turbine performance in ducted configuration. Savonius type turbines were tested as a function of air flux oscillation frequency. In more details, a turbine with an overlap ratio of 1/6 was used, while three air flux oscillating frequencies are imposed: 0.1, 0.5, 1 and 1.5?Hz. In order to measure turbine performance, a specific experimental setup was built, based on an OWC simulator. The testing tube (operating as power take-off simulator) was built using transparent materials to allow Particle Image Velocimetry measurement. A simple band brake system was used to apply load to turbine shaft and to measure turbine torque. Therefore, turbine torque, rotational speed, pressure drop and input air velocity were registered and turbine power and power coefficient as a function of tip speed ratio were calculated.
2019
Inglese
AIP Conference Proceedings
American Institute of Physics Inc.
New York
STATI UNITI D'AMERICA
ELETTRONICO
no
2191
020027-1
020027-9
9
978-073541938-4
74th Conference of the Italian Thermal Machines Engineering Association, ATI 2019
Modena
11-13/09/2019
Nazionale
http://scitation.aip.org/content/aip/proceeding/aipcp
no
Esperti anonimi
Compressed Air Energy Storage, Electricity Storage, Arbitrage
no
reserved
Brusca, S.; Famoso, F.; Galvagno, A.; Lanzafame, R.; Mauro, S.; Messina, M.; Prestipino, M.
7
14.d Contributo in Atti di Convegno::14.d.3 Contributi in extenso in Atti di convegno
273
info:eu-repo/semantics/conferenceObject
File in questo prodotto:
File Dimensione Formato  
2019 - Vertical axis air turbine in oscillating water column systems.pdf

solo gestori archivio

Descrizione: Article
Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.23 MB
Formato Adobe PDF
1.23 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3149939
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
social impact