This paper deals with a novel hybrid transformer configuration able to face power quality issues occurring on modern distribution grids integrating distributed generation from renewable energy sources and non-linear power electronic loads. The proposed system encompasses a three-phase distribution transformer with secondary windings arranged according to an open-end configuration and a three-phase inverter with floating DC bus. Unlike previous hybrid transformers the proposed one does not require a bidirectional converter to manage bidirectional power flows, neither a tertiary winding to supply the inverter, thus allowing the use of standard MV-LV distribution transformers with simple modifications. The obtained power conversion system can be exploited to perform a voltage control at the distribution grid edge, a reactive power management and harmonic pollution mitigation. Simulations confirm the effectiveness of the proposed solution, ensuring high power quality voltage control under unbalanced grid and load conditions.
An Open-End Winding Hybrid Transformer
S. FotiPrimo
Investigation
;S. De CaroSecondo
Investigation
;A. TestaSupervision
;
2020-01-01
Abstract
This paper deals with a novel hybrid transformer configuration able to face power quality issues occurring on modern distribution grids integrating distributed generation from renewable energy sources and non-linear power electronic loads. The proposed system encompasses a three-phase distribution transformer with secondary windings arranged according to an open-end configuration and a three-phase inverter with floating DC bus. Unlike previous hybrid transformers the proposed one does not require a bidirectional converter to manage bidirectional power flows, neither a tertiary winding to supply the inverter, thus allowing the use of standard MV-LV distribution transformers with simple modifications. The obtained power conversion system can be exploited to perform a voltage control at the distribution grid edge, a reactive power management and harmonic pollution mitigation. Simulations confirm the effectiveness of the proposed solution, ensuring high power quality voltage control under unbalanced grid and load conditions.File | Dimensione | Formato | |
---|---|---|---|
EPQ5543.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
2.13 MB
Formato
Adobe PDF
|
2.13 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.