In the last decades, due to the growing population, civil engineers faced with the problem of the design of adjacent buildings in limited areas; this could lead to mutual pounding if those structures are subjected to dynamic excitation such as ground motion accelerations. Among the possible solutions to this problem, the connection with vibration control devices, such as dampers, could be an innovative way. The sensitivity analysis represents a powerful tool in the optimization procedure, especially when the design of vibration control devices is required; in fact, it is possible to determine the alterations of the structural response with the reference structural parameters changes. In this paper a method for the evaluation of the sensitivity of the response of two adjacent buildings connected through fluid dampers is presented; the sensitivity of the structural response statistics is obtained through very simple frequency domain integrals. The proposed approach requires the evaluation of explicit closed form solutions of the derivatives of time-frequency response vector functions with respect to the parameters, that define the modified structural model.

Response Sensitivity of Damper-connected Adjacent Structural Systems Subjected to Fully Non-stationary Random Excitations

Muscolino Giuseppe
Primo
;
Genovese Federica
Secondo
;
Alderucci Tiziana
Ultimo
2021-01-01

Abstract

In the last decades, due to the growing population, civil engineers faced with the problem of the design of adjacent buildings in limited areas; this could lead to mutual pounding if those structures are subjected to dynamic excitation such as ground motion accelerations. Among the possible solutions to this problem, the connection with vibration control devices, such as dampers, could be an innovative way. The sensitivity analysis represents a powerful tool in the optimization procedure, especially when the design of vibration control devices is required; in fact, it is possible to determine the alterations of the structural response with the reference structural parameters changes. In this paper a method for the evaluation of the sensitivity of the response of two adjacent buildings connected through fluid dampers is presented; the sensitivity of the structural response statistics is obtained through very simple frequency domain integrals. The proposed approach requires the evaluation of explicit closed form solutions of the derivatives of time-frequency response vector functions with respect to the parameters, that define the modified structural model.
2021
9783030773137
9783030773144
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3316870
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact