The main aim of the present paper is the evaluation of the effects of the instrumental energy resolution on the mean square displacement (MSD) obtained by elastic incoherent neutron scattering (EINS). In particular, this study is performed in the time domain, through the time-Fourier transform of the elastically scattered neutron intensity, and is mainly focused on the connection between the system MSD and the measured MSD. It is shown how in the case of EINS, the instrumental energy resolution gives rise to the time integration of the time-dependent system MSD function weighted in time by the resolution function. The formulated approach is applied to the data collected on dry and hydrated (H2O and D2O with h = 0.4) lysozyme samples by two spectrometers working with a different instrumental resolution (the IN10 and IN13 spectrometers of the Institute Laue-Langevin). As a result, the procedure furnishes an excellent agreement for the system MSD evaluated in the low temperature range up to T = 40 K.

Mean Square Displacements from Elastic Incoherent Neutron Scattering Evaluated by Spectrometers Working with Different Energy Resolution on Dry and Hydrated (H2O and D2O) Lysozyme

MAGAZU', Salvatore;MIGLIARDO, Federica;BENEDETTO, ANTONIO
2010-01-01

Abstract

The main aim of the present paper is the evaluation of the effects of the instrumental energy resolution on the mean square displacement (MSD) obtained by elastic incoherent neutron scattering (EINS). In particular, this study is performed in the time domain, through the time-Fourier transform of the elastically scattered neutron intensity, and is mainly focused on the connection between the system MSD and the measured MSD. It is shown how in the case of EINS, the instrumental energy resolution gives rise to the time integration of the time-dependent system MSD function weighted in time by the resolution function. The formulated approach is applied to the data collected on dry and hydrated (H2O and D2O with h = 0.4) lysozyme samples by two spectrometers working with a different instrumental resolution (the IN10 and IN13 spectrometers of the Institute Laue-Langevin). As a result, the procedure furnishes an excellent agreement for the system MSD evaluated in the low temperature range up to T = 40 K.
2010
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1906076
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact