AIM:To compare pancreatic virtual unenhanced (VUE) and true unenhanced (TUE) images and to calculate the potential dose reduction by omitting the conventional unenhanced scan. MATERIALS AND METHODS: Fifty-one patients with known or suspected pancreatic masses underwent contrast-enhanced computed-tomography (CT) during unenhanced and portal venous phases acquired in single-energy (SE) mode, and pancreatic parenchymal phase acquired in dual-energy (DE) mode. The image quality (IQ) and image noise (IN) of TUE and VUE images were evaluated. The effective dose of a combined DE/SE dual-phase protocol was compared with that of a theoretical standard SE triple-phase protocol. The results were tested for statistical significance using the Cohen's k, the Wilcoxon's signed rank test, and the paired t-test; p-values of less than 0.05 were considered significant. RESULTS: Mean TUE and VUE IQ were 1.5 ± 0.6 and 1.6 ± 0.6 (k = 0.891), with no significant difference (p > 0.05). Mean TUE and VUE IN were 12.3 ± 1.6 and 10.3 ± 1.5 HU, and resulted significantly different (p < 0.001). Mean effective doses for a combined DE/SE dual-phase protocol and SE triple-phase protocol were 8.9 ± 2.4 mSv (range 4.8-16.2 mSv) and 12.1 ± 3.1 mSv (range 6.4-21.1 mSv). The calculated mean dose reduction achievable by omitting the unenhanced scan was 26.7 ± 9.7% (range 10-46.1; p < 0.001). CONCLUSION: VUE images are feasible for pancreatic abdominal CT. A combined DE/SE dual-phase protocol permits a significant reduction in dose exposure to patients.

Pancreatic dual-source dual-energy CT: is it time to discard unenhanced imaging?

MILETO, ACHILLE;MAZZIOTTI, Silvio;GAETA, Michele;BOTTARI, Antonio;ZIMBARO, FABRIZIO;GIARDINA, CLAUDIO;ASCENTI, Giorgio
2012-01-01

Abstract

AIM:To compare pancreatic virtual unenhanced (VUE) and true unenhanced (TUE) images and to calculate the potential dose reduction by omitting the conventional unenhanced scan. MATERIALS AND METHODS: Fifty-one patients with known or suspected pancreatic masses underwent contrast-enhanced computed-tomography (CT) during unenhanced and portal venous phases acquired in single-energy (SE) mode, and pancreatic parenchymal phase acquired in dual-energy (DE) mode. The image quality (IQ) and image noise (IN) of TUE and VUE images were evaluated. The effective dose of a combined DE/SE dual-phase protocol was compared with that of a theoretical standard SE triple-phase protocol. The results were tested for statistical significance using the Cohen's k, the Wilcoxon's signed rank test, and the paired t-test; p-values of less than 0.05 were considered significant. RESULTS: Mean TUE and VUE IQ were 1.5 ± 0.6 and 1.6 ± 0.6 (k = 0.891), with no significant difference (p > 0.05). Mean TUE and VUE IN were 12.3 ± 1.6 and 10.3 ± 1.5 HU, and resulted significantly different (p < 0.001). Mean effective doses for a combined DE/SE dual-phase protocol and SE triple-phase protocol were 8.9 ± 2.4 mSv (range 4.8-16.2 mSv) and 12.1 ± 3.1 mSv (range 6.4-21.1 mSv). The calculated mean dose reduction achievable by omitting the unenhanced scan was 26.7 ± 9.7% (range 10-46.1; p < 0.001). CONCLUSION: VUE images are feasible for pancreatic abdominal CT. A combined DE/SE dual-phase protocol permits a significant reduction in dose exposure to patients.
2012
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/2069021
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 55
social impact