Accessory mitral valve tissue (AMVT) is a rare congenital cardiac anomaly sometimes responsible for left ventricular outflow tract (LVOT) obstruction. It is diagnosed during both neonate-childhood and adult periods in patients usually symptomatic for dyspnoea, chest pain, palpitations, fatigue, or syncope. Nevertheless, AMVT is often an incidental finding. AMVT is most often associated with other cardiac and vascular congenital malformations, such as septal defects and transposition of the great arteries. Surgery is indicated only in cases of significant LVOT obstruction and in patients undergoing correction of other cardiac malformations or exploration of an intracardiac mass. Two-dimensional echocardiography, both transthoracic and transoesophageal, is considered the main imaging modality for AMVT diagnosis and patient follow-up. The recent introduction of three-dimensional echocardiography allows a more realistic characterization of this entity. We present three clinical cases in which AMVT was incidentally diagnosed during standard echocardiography and an updated review of the literature highlighting the usefulness of echocardiography for AMVT morphological and functional characterization as well as the most relevant clinical implications due to its discovery.

Accessory mitral valve tissue: an updated review of the literature

MANGANARO, ROBERTA;ZITO, Concetta;ORETO, Giuseppe;CARERJ, Scipione
2014-01-01

Abstract

Accessory mitral valve tissue (AMVT) is a rare congenital cardiac anomaly sometimes responsible for left ventricular outflow tract (LVOT) obstruction. It is diagnosed during both neonate-childhood and adult periods in patients usually symptomatic for dyspnoea, chest pain, palpitations, fatigue, or syncope. Nevertheless, AMVT is often an incidental finding. AMVT is most often associated with other cardiac and vascular congenital malformations, such as septal defects and transposition of the great arteries. Surgery is indicated only in cases of significant LVOT obstruction and in patients undergoing correction of other cardiac malformations or exploration of an intracardiac mass. Two-dimensional echocardiography, both transthoracic and transoesophageal, is considered the main imaging modality for AMVT diagnosis and patient follow-up. The recent introduction of three-dimensional echocardiography allows a more realistic characterization of this entity. We present three clinical cases in which AMVT was incidentally diagnosed during standard echocardiography and an updated review of the literature highlighting the usefulness of echocardiography for AMVT morphological and functional characterization as well as the most relevant clinical implications due to its discovery.
2014
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/2652578
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 29
social impact