BACKGROUND: The aim of this paper is to underline the prosthodontics components features of two different overdenture retention systems on dental implants. The use of titanium, dental implants for replacing missing teeth is today considered to be a predictable procedure giving the patients esthetic and function for long time. METHODS: Finite element analysis (FEA) and tests based on the Von Mises criterion have been applied in order to evaluate the stress distribution over two different prosthodontics retention systems. Two models with the ball attachment and with the Locator® systems have been created and put on simulated chewing stresses. RESULTS: The two systems were subjected to axial and oblique forces and both guaranteed good results over simulated masticatory cycle. However, the Locator system seemed to better respond to the overall load distributions. CONCLUSIONS: Clinicians should choose the better prosthetic solution for the ridge they want to restore. Both retention systems offer long-term success if applied following the manufacture guide limitations and suggestions.

Three dimensional evaluation of different implant prosthetic retention systems: fem e von mises study

RUNCI, MICHELE;CERVINO, GABRIELE;Fiorillo, Luca;BRAMANTI, ennio;CICCIU', Marco
2016-01-01

Abstract

BACKGROUND: The aim of this paper is to underline the prosthodontics components features of two different overdenture retention systems on dental implants. The use of titanium, dental implants for replacing missing teeth is today considered to be a predictable procedure giving the patients esthetic and function for long time. METHODS: Finite element analysis (FEA) and tests based on the Von Mises criterion have been applied in order to evaluate the stress distribution over two different prosthodontics retention systems. Two models with the ball attachment and with the Locator® systems have been created and put on simulated chewing stresses. RESULTS: The two systems were subjected to axial and oblique forces and both guaranteed good results over simulated masticatory cycle. However, the Locator system seemed to better respond to the overall load distributions. CONCLUSIONS: Clinicians should choose the better prosthetic solution for the ridge they want to restore. Both retention systems offer long-term success if applied following the manufacture guide limitations and suggestions.
2016
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3093864
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 29
  • Scopus 55
  • ???jsp.display-item.citation.isi??? 39
social impact