This paper reports on the high sensitivity of sub-spherical In2O3-Pt nanoparticles (NPs) for detecting ppb levels of acetone, a biomarker for diabetes. The In2O3-Pt NPs, in the form of monodisperse metal-oxide In2O3 NPs with diameters of 6-8 nm, decorated with 2 wt% Pt metal NPs (2-3 nm) on the surface, were synthesized by a novel non-aqueous sol-gel route. NPs samples were investigated by X-ray powder diffraction (XRPD), using the advanced whole powder pattern modeling (WPPM) method, and high-resolution transmission electron microscopy (HR-TEM). The advantage of this preparative process is that it preserves metallic platinum NPs formed during the synthesis. The highly sensitive acetone sensor based on these NPs, showed a lower detection limit as low as 10 ppb or less, which is the lowest detection limit ever reported for any chemoresistive acetone sensors. This exceptional performance is likely due to the key role played by very small Pt metal NPs uniformly distributed in the In2O3-Pt nanostructure. The developed sensor would be suitable for use as a highly sensitive, practical breath acetone checker for daily diet and diabetes management and diagnosis. © 2016 Elsevier B.V.

Pt-decorated In2O3 nanoparticles and their ability as a highly sensitive (<10 ppb) acetone sensor for biomedical applications

LEONARDI, SALVATORE GIANLUCA
Secondo
;
LATINO, MARIANGELA;DONATO, Nicola;NERI, Giovanni
Ultimo
2016-01-01

Abstract

This paper reports on the high sensitivity of sub-spherical In2O3-Pt nanoparticles (NPs) for detecting ppb levels of acetone, a biomarker for diabetes. The In2O3-Pt NPs, in the form of monodisperse metal-oxide In2O3 NPs with diameters of 6-8 nm, decorated with 2 wt% Pt metal NPs (2-3 nm) on the surface, were synthesized by a novel non-aqueous sol-gel route. NPs samples were investigated by X-ray powder diffraction (XRPD), using the advanced whole powder pattern modeling (WPPM) method, and high-resolution transmission electron microscopy (HR-TEM). The advantage of this preparative process is that it preserves metallic platinum NPs formed during the synthesis. The highly sensitive acetone sensor based on these NPs, showed a lower detection limit as low as 10 ppb or less, which is the lowest detection limit ever reported for any chemoresistive acetone sensors. This exceptional performance is likely due to the key role played by very small Pt metal NPs uniformly distributed in the In2O3-Pt nanostructure. The developed sensor would be suitable for use as a highly sensitive, practical breath acetone checker for daily diet and diabetes management and diagnosis. © 2016 Elsevier B.V.
2016
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0925400516302490-main.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.79 MB
Formato Adobe PDF
2.79 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3095540
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 93
  • ???jsp.display-item.citation.isi??? 88
social impact