Internal dosimetry is a fundamental instrument for the personalization of nuclear medicine therapies, to maximize the therapeutic effect while minimizing the radiation burden to other organs. Three-dimensional (3D) dosimetry can quantify the impact of heterogeneous radiopharmaceutical distributions in organs, lesions and tissues. We analysed the influence of radionuclide voxel S factors in 3D dosimetry of 111In, 177Lu and 90Y, the most used radionuclides in Peptide Receptor Radionuclide Therapy (PRRT). Calculations were carried out for kidneys on a workstation equipped with a software for 3D dosimetry (Imalytics STRATOS, Philips AG), adopting a computational anthropomorphic phantom and, retrospectively, the SPECT-CT image series of a clinical case of PRRT. Two sets of voxel S factors were adopted: the pre-loaded Philips kernels, calculated by direct Monte Carlo simulation, and the ones calculated through a previously proposed analytical approach. Philips 111In kernel did not account for mono-energetic Auger or Conversion electrons. Results indicate a difference of about −32% in voxel S factors for 111In in 4.42 mm voxel size and around −35% in 4.80 mm voxel size, particularly self-dose values; this lead to significant shift in dose histograms and average doses. For 177Lu and 90Y, differences are about 2% and 12% for 4.42 mm voxels and about −8% and 9% for 4.80 mm voxels, respectively, attributable to the different calculation methods of the voxel S factors; this does not lead to significant discrepancies between the two dose histograms. Consequently, voxel S factors must account accurately for all radiations emitted by the nuclide.

Influence of voxel S factors on three-dimensional internal dosimetry calculations

AMATO, ERNESTO;BALDARI, Sergio
2016-01-01

Abstract

Internal dosimetry is a fundamental instrument for the personalization of nuclear medicine therapies, to maximize the therapeutic effect while minimizing the radiation burden to other organs. Three-dimensional (3D) dosimetry can quantify the impact of heterogeneous radiopharmaceutical distributions in organs, lesions and tissues. We analysed the influence of radionuclide voxel S factors in 3D dosimetry of 111In, 177Lu and 90Y, the most used radionuclides in Peptide Receptor Radionuclide Therapy (PRRT). Calculations were carried out for kidneys on a workstation equipped with a software for 3D dosimetry (Imalytics STRATOS, Philips AG), adopting a computational anthropomorphic phantom and, retrospectively, the SPECT-CT image series of a clinical case of PRRT. Two sets of voxel S factors were adopted: the pre-loaded Philips kernels, calculated by direct Monte Carlo simulation, and the ones calculated through a previously proposed analytical approach. Philips 111In kernel did not account for mono-energetic Auger or Conversion electrons. Results indicate a difference of about −32% in voxel S factors for 111In in 4.42 mm voxel size and around −35% in 4.80 mm voxel size, particularly self-dose values; this lead to significant shift in dose histograms and average doses. For 177Lu and 90Y, differences are about 2% and 12% for 4.42 mm voxels and about −8% and 9% for 4.80 mm voxels, respectively, attributable to the different calculation methods of the voxel S factors; this does not lead to significant discrepancies between the two dose histograms. Consequently, voxel S factors must account accurately for all radiations emitted by the nuclide.
2016
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3103782
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact