ACPA (anti-citrullinated protein antibody) tests are today systematically added to clinical and radiological investigations when diagnosing rheumatoid arthritis (RA), and the inclusion of ACPA positivity in the new 2010 RA criteria underlines their importance. The aim of this study was to determine the sensitivity and specificity of different ACPA assays and IgA, IgG and IgM isotypes of rheumatoid factor (RF) in a cohort of patients with early RA in order to assess the value of combining the tests. The serum samples were obtained from 46 RA patients, 80 patients with systemic rheumatic disease, and 20 blood donors. ACPAs were measured using five different commercial kits. The receiver operating characteristic (ROC) curves of the anti-ACPA tests had area under the curve (AUC) values of 0.60-0.83. The diagnostic accuracy of the Bio-Rad multiplex flow immunoassay, a new technology for ACPA testing, was very similar to that of the other widely used commercial immunoassays. The EliA CCP-Phadia test was the most specific, and had the best positive likelihood ratio and positive predictive values, whereas the anti-CCP Inova 3.1 test was the most sensitive, and had the best negative likelihood ratio and negative predictive values. The best combination to use for early RA screening was an ACPA test together with IgM and IgA RF.

Anti-citrullinated peptide antibodies and rheumatoid factor isotypes in the diagnosis of rheumatoid arthritis: An assessment of combined tests

Atzeni, Fabiola
;
2014-01-01

Abstract

ACPA (anti-citrullinated protein antibody) tests are today systematically added to clinical and radiological investigations when diagnosing rheumatoid arthritis (RA), and the inclusion of ACPA positivity in the new 2010 RA criteria underlines their importance. The aim of this study was to determine the sensitivity and specificity of different ACPA assays and IgA, IgG and IgM isotypes of rheumatoid factor (RF) in a cohort of patients with early RA in order to assess the value of combining the tests. The serum samples were obtained from 46 RA patients, 80 patients with systemic rheumatic disease, and 20 blood donors. ACPAs were measured using five different commercial kits. The receiver operating characteristic (ROC) curves of the anti-ACPA tests had area under the curve (AUC) values of 0.60-0.83. The diagnostic accuracy of the Bio-Rad multiplex flow immunoassay, a new technology for ACPA testing, was very similar to that of the other widely used commercial immunoassays. The EliA CCP-Phadia test was the most specific, and had the best positive likelihood ratio and positive predictive values, whereas the anti-CCP Inova 3.1 test was the most sensitive, and had the best negative likelihood ratio and negative predictive values. The best combination to use for early RA screening was an ACPA test together with IgM and IgA RF.
2014
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3125312
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact