Determination of Legionella concentrations in water networks is useful for predicting legionellosis risks. The standard culture technique using concentration with membranes filters is the most commonly used method for environmental surveillance of Legionella. The aim of this study was to verify whether filtration with different filter pore sizes (0.2 and 0.45 µm) according to (ISO) 11731:2017, followed by directly placing them on culture media, can influence Legionella detection. Three laboratories participated in an experimental study that tested a known suspension of Legionella pneumophila (Lpn) serogroup 1 (ATCC 33152) (approximate final cell density of 15 CFU/mL). E. coli (ATCC 11775) and Pseudomonas aeruginosa (ATCC 25668) were included as control tests. The average (95% CI) percentage of recovery of Lpn was 65% using 0.45-µm filters and 15% using 0.2-µm filters (p < 0.0001). For control tests, the average (95% CI) percentage of recovery was higher with 0.45 vs. 0.2 µm filters: 97% vs. 64% for Escherichia coli (p < 0.00001) and 105% vs. 97% (p = 0.0244) for P. aeruginosa. Our results showed that the 0.45-µm filters provided the greatest detection of Legionella. Because the current national guidelines leave the choice of membrane porosity to the operator, experimental studies are important for directing operators towards a conscious choice to standardize Legionella environmental surveillance methods.

Legionella Detection in Water Networks as per ISO 11731:2017: Can Different Filter Pore Sizes and Direct Placement on Culture Media Influence Laboratory Results?

Laganà, Pasqualina;
2020-01-01

Abstract

Determination of Legionella concentrations in water networks is useful for predicting legionellosis risks. The standard culture technique using concentration with membranes filters is the most commonly used method for environmental surveillance of Legionella. The aim of this study was to verify whether filtration with different filter pore sizes (0.2 and 0.45 µm) according to (ISO) 11731:2017, followed by directly placing them on culture media, can influence Legionella detection. Three laboratories participated in an experimental study that tested a known suspension of Legionella pneumophila (Lpn) serogroup 1 (ATCC 33152) (approximate final cell density of 15 CFU/mL). E. coli (ATCC 11775) and Pseudomonas aeruginosa (ATCC 25668) were included as control tests. The average (95% CI) percentage of recovery of Lpn was 65% using 0.45-µm filters and 15% using 0.2-µm filters (p < 0.0001). For control tests, the average (95% CI) percentage of recovery was higher with 0.45 vs. 0.2 µm filters: 97% vs. 64% for Escherichia coli (p < 0.00001) and 105% vs. 97% (p = 0.0244) for P. aeruginosa. Our results showed that the 0.45-µm filters provided the greatest detection of Legionella. Because the current national guidelines leave the choice of membrane porosity to the operator, experimental studies are important for directing operators towards a conscious choice to standardize Legionella environmental surveillance methods.
2020
File in questo prodotto:
File Dimensione Formato  
ijerph-17-02077-v2.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 327.24 kB
Formato Adobe PDF
327.24 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3160115
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact