Objective The aim of this study was to evaluate the impact of a noise-optimized virtual monoenergetic imaging (VMI +) reconstruction technique on image quality and lesion delineation in patients with renal cell carcinoma (RCC) undergoing abdominal dual-energy computed tomography (DECT). Materials and methods Fifty-two patients (33 men; 61.5 ± 13.6 years) with RCC underwent contrast-enhanced DECT during the corticomedullary and nephrogenic phase of renal enhancement. DECT datasets were reconstructed with standard linearly-blended (M_0.6), as well as traditional virtual monoenergetic (VMI) and VMI+ algorithms in 10-keV increments from 40 to 100 keV. Contrast-to-noise (CNR) and tumor-to-cortex ratios for corticomedullary- and nephrogenic-phase images were objectively measured by a radiologist with 3 years of experience. Subjective image quality and RCC delineation were evaluated by three independent radiologists. Results Greatest CNR values were found for 40-keV VMI+ series in both corticomedullary- (8.9 ± 4.9) and nephrogenic-phase (7.1 ± 4.6) images and were significantly higher compared to all other reconstructions (P < 0.001). Furthermore, tumor-to-cortex ratios were highest for 40-keV nephrogenic-phase VMI+ (2.1 ± 3.5; P ≤ 0.016), followed by 50-keV and 60-keV VMI+ (2.0 ± 3.2 and 1.8 ± 2.8, respectively). Qualitative image quality scored highest for 50-keV VMI+ series in corticomedullary-phase reconstructions and 60-keV in nephrogenic-phase reconstructions (P ≤ 0.031). Highest scores for lesion delineation were assigned for 40-keV VMI+ reconstructions (P ≤ 0.074). Conclusion Low-keV VMI+ reconstructions lead to improved image quality and lesion delineation of corticomedullary- and nephrogenic-phase DECT datasets in patients with RCC.

Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma

D'Angelo T.
Membro del Collaboration Group
;
2017-01-01

Abstract

Objective The aim of this study was to evaluate the impact of a noise-optimized virtual monoenergetic imaging (VMI +) reconstruction technique on image quality and lesion delineation in patients with renal cell carcinoma (RCC) undergoing abdominal dual-energy computed tomography (DECT). Materials and methods Fifty-two patients (33 men; 61.5 ± 13.6 years) with RCC underwent contrast-enhanced DECT during the corticomedullary and nephrogenic phase of renal enhancement. DECT datasets were reconstructed with standard linearly-blended (M_0.6), as well as traditional virtual monoenergetic (VMI) and VMI+ algorithms in 10-keV increments from 40 to 100 keV. Contrast-to-noise (CNR) and tumor-to-cortex ratios for corticomedullary- and nephrogenic-phase images were objectively measured by a radiologist with 3 years of experience. Subjective image quality and RCC delineation were evaluated by three independent radiologists. Results Greatest CNR values were found for 40-keV VMI+ series in both corticomedullary- (8.9 ± 4.9) and nephrogenic-phase (7.1 ± 4.6) images and were significantly higher compared to all other reconstructions (P < 0.001). Furthermore, tumor-to-cortex ratios were highest for 40-keV nephrogenic-phase VMI+ (2.1 ± 3.5; P ≤ 0.016), followed by 50-keV and 60-keV VMI+ (2.0 ± 3.2 and 1.8 ± 2.8, respectively). Qualitative image quality scored highest for 50-keV VMI+ series in corticomedullary-phase reconstructions and 60-keV in nephrogenic-phase reconstructions (P ≤ 0.031). Highest scores for lesion delineation were assigned for 40-keV VMI+ reconstructions (P ≤ 0.074). Conclusion Low-keV VMI+ reconstructions lead to improved image quality and lesion delineation of corticomedullary- and nephrogenic-phase DECT datasets in patients with RCC.
2017
File in questo prodotto:
File Dimensione Formato  
Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.15 MB
Formato Adobe PDF
2.15 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3166877
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 27
social impact