Background: Stereotactic radiosurgery (SRS) is an effective treatment for trigeminal neuralgia (TN). Nevertheless, a proportion of patients will experience recurrence and treatment-related sensory disturbances. In order to evaluate the predictors of efficacy and safety of image-guided non-isocentric radiosurgery, we analyzed the impact of trigeminal nerve volume and the nerve dose/volume relationship, together with relevant clinical characteristics. Methods: Two-hundred and ninety-six procedures were performed on 262 patients at three centers. In 17 patients the TN was secondary to multiple sclerosis (MS). Trigeminal pain and sensory disturbances were classified according to the Barrow Neurological Institute (BNI) scale. Pain-free-intervals were investigated using Kaplan Meier analyses. Univariate and multivariate Cox regression analyses were performed to identify predictors. Results: The median follow-up period was 38 months, median maximal dose 72.4 Gy, median target nerve volume 25 mm3, and median prescription dose 60 Gy. Pain control rate (BNI I-III) at 6, 12, 24, 36, 48, and 60 months were 96.8, 90.9, 84.2, 81.4, 74.2, and 71.2%, respectively. Overall, 18% of patients developed sensory disturbances. Patients with volume ≥ 30 mm3 were more likely to maintain pain relief (p = 0.031), and low integral dose (< 1.4 mJ) tended to be associated with more pain recurrence than intermediate (1.4-2.7 mJ) or high integral dose (> 2.7 mJ; low vs. intermediate: log-rank test, χ2 = 5.02, p = 0.019; low vs. high: log-rank test, χ2 = 6.026, p = 0.014). MS, integral dose, and mean dose were the factors associated with pain recurrence, while re-irradiation and MS were predictors for sensory disturbance in the multivariate analysis. Conclusions: The dose to nerve volume ratio is predictive of pain recurrence in TN, and re-irradiation has a major impact on the development of sensory disturbances after non-isocentric SRS. Interestingly, the integral dose may differ significantly in treatments using apparently similar dose and volume constraints.
Factors affecting outcome in frameless non-isocentric stereotactic radiosurgery for trigeminal neuralgia: A multicentric cohort study
Pontoriero A.;Cacciola A.;Iati G.;Pergolizzi S.;Parisi S.;
2020-01-01
Abstract
Background: Stereotactic radiosurgery (SRS) is an effective treatment for trigeminal neuralgia (TN). Nevertheless, a proportion of patients will experience recurrence and treatment-related sensory disturbances. In order to evaluate the predictors of efficacy and safety of image-guided non-isocentric radiosurgery, we analyzed the impact of trigeminal nerve volume and the nerve dose/volume relationship, together with relevant clinical characteristics. Methods: Two-hundred and ninety-six procedures were performed on 262 patients at three centers. In 17 patients the TN was secondary to multiple sclerosis (MS). Trigeminal pain and sensory disturbances were classified according to the Barrow Neurological Institute (BNI) scale. Pain-free-intervals were investigated using Kaplan Meier analyses. Univariate and multivariate Cox regression analyses were performed to identify predictors. Results: The median follow-up period was 38 months, median maximal dose 72.4 Gy, median target nerve volume 25 mm3, and median prescription dose 60 Gy. Pain control rate (BNI I-III) at 6, 12, 24, 36, 48, and 60 months were 96.8, 90.9, 84.2, 81.4, 74.2, and 71.2%, respectively. Overall, 18% of patients developed sensory disturbances. Patients with volume ≥ 30 mm3 were more likely to maintain pain relief (p = 0.031), and low integral dose (< 1.4 mJ) tended to be associated with more pain recurrence than intermediate (1.4-2.7 mJ) or high integral dose (> 2.7 mJ; low vs. intermediate: log-rank test, χ2 = 5.02, p = 0.019; low vs. high: log-rank test, χ2 = 6.026, p = 0.014). MS, integral dose, and mean dose were the factors associated with pain recurrence, while re-irradiation and MS were predictors for sensory disturbance in the multivariate analysis. Conclusions: The dose to nerve volume ratio is predictive of pain recurrence in TN, and re-irradiation has a major impact on the development of sensory disturbances after non-isocentric SRS. Interestingly, the integral dose may differ significantly in treatments using apparently similar dose and volume constraints.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.