A fast HPLC method with fluorescence detector (FD) was developed for the determination of three tocopherols (TOCs) in milk samples from Modicana cattle breed. The ultrasound-assisted procedure was optimized for the extraction of TOCs prior to HPLC/FD analysis, reducing sample preparation time and allowing a fast quantification of α-tocopherol, δ-tocopherol and γ tocopherol. The optimized ultrasonic extraction combines an efficient and simple saponification at room temperature and a rapid HPLC quantification of TOCs in milk. The precision of the full analytical procedure was satisfactory and the recoveries at three spiked levels were between 95.3% and 87.8%. The linear correlations were evaluated (R2 > 0.99) and the relative standard deviation (RSD) values for intra-day and inter-day tests at three spiked levels were below 1% for the retention time and below 5.20% for the area at low level spiking. The proposed procedure, reducing the experimental complexity, allowed accurate extraction and detection of three TOCs in milk samples from Modicana cattle breed.

A Fast and Efficient Ultrasound-Assisted Extraction of Tocopherols in Cow Milk Followed by HPLC Determination

Rotondo, Archimede
Primo
Writing – Review & Editing
;
La Torre, Giovanna Loredana
Secondo
Conceptualization
;
Gervasi, Teresa
Validation
;
2021-01-01

Abstract

A fast HPLC method with fluorescence detector (FD) was developed for the determination of three tocopherols (TOCs) in milk samples from Modicana cattle breed. The ultrasound-assisted procedure was optimized for the extraction of TOCs prior to HPLC/FD analysis, reducing sample preparation time and allowing a fast quantification of α-tocopherol, δ-tocopherol and γ tocopherol. The optimized ultrasonic extraction combines an efficient and simple saponification at room temperature and a rapid HPLC quantification of TOCs in milk. The precision of the full analytical procedure was satisfactory and the recoveries at three spiked levels were between 95.3% and 87.8%. The linear correlations were evaluated (R2 > 0.99) and the relative standard deviation (RSD) values for intra-day and inter-day tests at three spiked levels were below 1% for the retention time and below 5.20% for the area at low level spiking. The proposed procedure, reducing the experimental complexity, allowed accurate extraction and detection of three TOCs in milk samples from Modicana cattle breed.
2021
File in questo prodotto:
File Dimensione Formato  
2021 - Molecules-26-04645-v2.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.24 MB
Formato Adobe PDF
1.24 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3208328
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact