A fast HPLC method with fluorescence detector (FD) was developed for the determination of three tocopherols (TOCs) in milk samples from Modicana cattle breed. The ultrasound-assisted procedure was optimized for the extraction of TOCs prior to HPLC/FD analysis, reducing sample preparation time and allowing a fast quantification of α-tocopherol, δ-tocopherol and γ tocopherol. The optimized ultrasonic extraction combines an efficient and simple saponification at room temperature and a rapid HPLC quantification of TOCs in milk. The precision of the full analytical procedure was satisfactory and the recoveries at three spiked levels were between 95.3% and 87.8%. The linear correlations were evaluated (R2 > 0.99) and the relative standard deviation (RSD) values for intra-day and inter-day tests at three spiked levels were below 1% for the retention time and below 5.20% for the area at low level spiking. The proposed procedure, reducing the experimental complexity, allowed accurate extraction and detection of three TOCs in milk samples from Modicana cattle breed.
A Fast and Efficient Ultrasound-Assisted Extraction of Tocopherols in Cow Milk Followed by HPLC Determination
Rotondo, ArchimedePrimo
Writing – Review & Editing
;La Torre, Giovanna Loredana
Secondo
Conceptualization
;Gervasi, TeresaValidation
;
2021-01-01
Abstract
A fast HPLC method with fluorescence detector (FD) was developed for the determination of three tocopherols (TOCs) in milk samples from Modicana cattle breed. The ultrasound-assisted procedure was optimized for the extraction of TOCs prior to HPLC/FD analysis, reducing sample preparation time and allowing a fast quantification of α-tocopherol, δ-tocopherol and γ tocopherol. The optimized ultrasonic extraction combines an efficient and simple saponification at room temperature and a rapid HPLC quantification of TOCs in milk. The precision of the full analytical procedure was satisfactory and the recoveries at three spiked levels were between 95.3% and 87.8%. The linear correlations were evaluated (R2 > 0.99) and the relative standard deviation (RSD) values for intra-day and inter-day tests at three spiked levels were below 1% for the retention time and below 5.20% for the area at low level spiking. The proposed procedure, reducing the experimental complexity, allowed accurate extraction and detection of three TOCs in milk samples from Modicana cattle breed.File | Dimensione | Formato | |
---|---|---|---|
2021 - Molecules-26-04645-v2.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
1.24 MB
Formato
Adobe PDF
|
1.24 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.