Purpose: Diffusion-weighted imaging with the calculation of an apparent diffusion coefficient (ADC) has been proposed as a quantitative biomarker on contrast-enhanced MRI (CE-MRI) of the breast. There is a need to approve a generalizable ADC cutoff. The purpose of this study was to evaluate whether a predefined ADC cutoff allows downgrading of BI-RADS 4 lesions on CE-MRI, avoiding unnecessary biopsies. Experimental Design: This was a retrospective, multicentric, cross-sectional study. Data from five centers were pooled on the individual lesion level. Eligible patients had a BI-RADS 4 rating on CE-MRI. For each center, two breast radiologists evaluated the images. Data on lesion morphology (mass, non-mass), size, and ADC were collected. Histology was the standard of reference. A previously suggested ADC cutoff (≥1.5 × 10-3 mm2/second) was applied. A negative likelihood ratio of 0.1 or lower was considered as a rule-out criterion for breast cancer. Diagnostic performance indices were calculated by ROC analysis. Results: There were 657 female patients (mean age, 42; SD, 14.1) with 696 BI-RADS 4 lesions included. Disease prevalence was 59.5% (414/696). The area under the ROC curve was 0.784. Applying the investigated ADC cutoff, sensitivity was 96.6% (400/414). The potential reduction of unnecessary biopsies was 32.6% (92/282). Conclusions: An ADC cutoff of .1.5×10-3 mm2/second allows downgrading of lesions classified as BI-RADS 4 on breast CE-MRI. One-third of unnecessary biopsies could thus be avoided.

Diffusion-weighted Imaging Allows for Downgrading MR BI-RADS 4 Lesions in Contrast-enhanced MRI of the Breast to Avoid Unnecessary Biopsy

Marino M. A.
Membro del Collaboration Group
;
2021-01-01

Abstract

Purpose: Diffusion-weighted imaging with the calculation of an apparent diffusion coefficient (ADC) has been proposed as a quantitative biomarker on contrast-enhanced MRI (CE-MRI) of the breast. There is a need to approve a generalizable ADC cutoff. The purpose of this study was to evaluate whether a predefined ADC cutoff allows downgrading of BI-RADS 4 lesions on CE-MRI, avoiding unnecessary biopsies. Experimental Design: This was a retrospective, multicentric, cross-sectional study. Data from five centers were pooled on the individual lesion level. Eligible patients had a BI-RADS 4 rating on CE-MRI. For each center, two breast radiologists evaluated the images. Data on lesion morphology (mass, non-mass), size, and ADC were collected. Histology was the standard of reference. A previously suggested ADC cutoff (≥1.5 × 10-3 mm2/second) was applied. A negative likelihood ratio of 0.1 or lower was considered as a rule-out criterion for breast cancer. Diagnostic performance indices were calculated by ROC analysis. Results: There were 657 female patients (mean age, 42; SD, 14.1) with 696 BI-RADS 4 lesions included. Disease prevalence was 59.5% (414/696). The area under the ROC curve was 0.784. Applying the investigated ADC cutoff, sensitivity was 96.6% (400/414). The potential reduction of unnecessary biopsies was 32.6% (92/282). Conclusions: An ADC cutoff of .1.5×10-3 mm2/second allows downgrading of lesions classified as BI-RADS 4 on breast CE-MRI. One-third of unnecessary biopsies could thus be avoided.
2021
Inglese
ELETTRONICO
American Association for Cancer Research Inc.
27
7
1941
1948
8
https://aacrjournals.org/clincancerres/article/27/7/1941/671890/Diffusion-weighted-Imaging-Allows-for-Downgrading
Internazionale
Esperti anonimi
Adult, Biopsy, Breast Neoplasms, Contrast Media, Cross-Sectional Studies, Diffusion Magnetic Resonance Imaging, Female, Humans, Image Enhancement, Middle Aged, Retrospective Studies, Breast imaging reporting and data system, Atypical ductal hyperplasia
info:eu-repo/semantics/article
Clauser, P.; Krug, B.; Bickel, H.; Dietzel, M.; Pinker, K.; Neuhaus, V. -F.; Marino, M. A.; Moschetta, M.; Troiano, N.; Helbich, T. H.; Baltzer, P. A....espandi
14.a Contributo in Rivista::14.a.1 Articolo su rivista
11
262
restricted
File in questo prodotto:
File Dimensione Formato  
AAM_1078-0432_ccr-20-3037v1.pdf

solo utenti autorizzati

Descrizione: Articolo principale - AAM
Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 6.01 MB
Formato Adobe PDF
6.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Marino_Diffusion-weighted Imaging Allows for Downgrading MR.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 581.31 kB
Formato Adobe PDF
581.31 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3208554
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 80
  • ???jsp.display-item.citation.isi??? 79
social impact