To investigate the value of contrast-enhanced mammography (CEM) compared to full-field digital mammography (FFDM) in screening breast cancer patients after breast-conserving surgery (BCS), this Health Insurance Portability and Accountability Act-compliant, institutional review board-approved retrospective, single-institution study included 971 CEM exams in 541 asymptomatic patients treated with BCS who underwent screening CEM between January 2013 and November 2018. Histopathology, or at least a one-year follow-up, was used as the standard of reference. Twenty-one of 541 patients (3.9%) were diagnosed with ipsi-or contralateral breast cancer: six (28.6%) cancers were seen with low-energy images (equivalent to FFDM), an additional nine (42.9%) cancers were detected only on iodine (contrast-enhanced) images, and six interval cancers were identified within 365 days of a negative screening CEM. Of the 10 ipsilateral cancers detected on CEM, four were detected on low-energy images (40%). Of the five contralateral cancers detected on CEM, two were detected on low-energy images (40%). Overall, the cancer detection rate (CDR) for CEM was 15.4/1000 (15/971), and the positive predictive value (PPV3) of the biopsies performed was 42.9% (15/35). For findings seen on low-energy images, with or without contrast, the CDR was 6.2/1000 (6/971), and the PPV3 of the biopsies performed was 37.5% (6/16). In the post-BCS screening setting, CEM has a higher CDR than FFDM.

Contrast-enhanced mammography for screening women after breast conserving surgery

Marino M. A.;
2020-01-01

Abstract

To investigate the value of contrast-enhanced mammography (CEM) compared to full-field digital mammography (FFDM) in screening breast cancer patients after breast-conserving surgery (BCS), this Health Insurance Portability and Accountability Act-compliant, institutional review board-approved retrospective, single-institution study included 971 CEM exams in 541 asymptomatic patients treated with BCS who underwent screening CEM between January 2013 and November 2018. Histopathology, or at least a one-year follow-up, was used as the standard of reference. Twenty-one of 541 patients (3.9%) were diagnosed with ipsi-or contralateral breast cancer: six (28.6%) cancers were seen with low-energy images (equivalent to FFDM), an additional nine (42.9%) cancers were detected only on iodine (contrast-enhanced) images, and six interval cancers were identified within 365 days of a negative screening CEM. Of the 10 ipsilateral cancers detected on CEM, four were detected on low-energy images (40%). Of the five contralateral cancers detected on CEM, two were detected on low-energy images (40%). Overall, the cancer detection rate (CDR) for CEM was 15.4/1000 (15/971), and the positive predictive value (PPV3) of the biopsies performed was 42.9% (15/35). For findings seen on low-energy images, with or without contrast, the CDR was 6.2/1000 (6/971), and the PPV3 of the biopsies performed was 37.5% (6/16). In the post-BCS screening setting, CEM has a higher CDR than FFDM.
2020
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3208556
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact