Testing HIV-1 RNA in plasma by PCR is universally accepted as the ultimate standard to confirm diagnosis of HIV-1 infection and to monitor viral load in patients under treatment. However, in some cases, this assay could either underestimate or overestimate the replication capacity of a circulating or latent virus. In the present study, we performed the assessment of evaluating the HIV-1 reverse transcriptase (RT) activity by means of a new assay for the functional screening of the status of HIV-1 patients. To this purpose, we utilized, for the first time on blood samples, an adapted version of a real-time RT quantitative PCR assay, utilized to evaluate the HIV-1-RT inhibitory activity of compounds. The study analyzed blood samples from 28 HIV-1-infected patients, exhibiting a wide range of viremia and immunological values. Results demonstrated that plasma HIV-1 RT levels, expressed as cycle threshold values obtained with the assay under appraisal, were inversely and highly significantly correlated with the plasma HIV-1-RNA levels of the patients. Thus, an HIV-1 RT quantitative PCR assay was created which we describe in this study, and it may be considered as a promising basis for an additional tool capable of furnishing information on the functional virological status of HIV-1-infected patients.

Appraisal of a simple and effective RT-qPCR assay for evaluating the reverse transcriptase activity in blood samples from HIV-1 patients

Marino-Merlo F.;
2020-01-01

Abstract

Testing HIV-1 RNA in plasma by PCR is universally accepted as the ultimate standard to confirm diagnosis of HIV-1 infection and to monitor viral load in patients under treatment. However, in some cases, this assay could either underestimate or overestimate the replication capacity of a circulating or latent virus. In the present study, we performed the assessment of evaluating the HIV-1 reverse transcriptase (RT) activity by means of a new assay for the functional screening of the status of HIV-1 patients. To this purpose, we utilized, for the first time on blood samples, an adapted version of a real-time RT quantitative PCR assay, utilized to evaluate the HIV-1-RT inhibitory activity of compounds. The study analyzed blood samples from 28 HIV-1-infected patients, exhibiting a wide range of viremia and immunological values. Results demonstrated that plasma HIV-1 RT levels, expressed as cycle threshold values obtained with the assay under appraisal, were inversely and highly significantly correlated with the plasma HIV-1-RNA levels of the patients. Thus, an HIV-1 RT quantitative PCR assay was created which we describe in this study, and it may be considered as a promising basis for an additional tool capable of furnishing information on the functional virological status of HIV-1-infected patients.
2020
File in questo prodotto:
File Dimensione Formato  
pathogens-09-01047.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 947.18 kB
Formato Adobe PDF
947.18 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3209010
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact