In veterinary medicine, the gold standard for assessing body temperature is rectal temperature assessment. Considering that this procedure is stressful for many species, in particular for cats, it could be clinically important to consider an alternative approach for the monitoring of core body temperature. The aim of this study was to test if cutaneous temperature measurements by means of different infrared thermometers are in agreement with the most commonly used method for body temperature measurement in cats. The cutaneous temperature was recorded in the jugular, shoulder, rib, flank, and inner thigh, using three different non-contact infrared thermometers (IR1, IR2, and IR3) in 20 cats. The cutaneous temperature was then compared to the rectal temperature, recorded by means of a digital thermometer. The obtained data indicated that the cutaneous temperature recorded by the infrared thermometers was not in agreement with the data recorded by the digital thermometer in the rectum. In cats, the use of non-contact infrared thermometers gave no reproducible or constant data to justify their application for the recording of body temperature instead of rectal temperature recording. In addition, the infrared temperature measurement devices generated results that were not in good agreement among themselves, providing a novel result of clinical importance.

Short Communication: Use of Infrared Thermometers for Cutaneous Temperature Recording: Agreement with the Rectal Temperature in Felis catus

Giannetto, Claudia
;
Acri, Giuseppe;Pennisi, Melissa;Piccione, Giuseppe;Arfuso, Francesca;Falcone, Annastella;Giudice, Elisabetta;Di Pietro, Simona
2022-01-01

Abstract

In veterinary medicine, the gold standard for assessing body temperature is rectal temperature assessment. Considering that this procedure is stressful for many species, in particular for cats, it could be clinically important to consider an alternative approach for the monitoring of core body temperature. The aim of this study was to test if cutaneous temperature measurements by means of different infrared thermometers are in agreement with the most commonly used method for body temperature measurement in cats. The cutaneous temperature was recorded in the jugular, shoulder, rib, flank, and inner thigh, using three different non-contact infrared thermometers (IR1, IR2, and IR3) in 20 cats. The cutaneous temperature was then compared to the rectal temperature, recorded by means of a digital thermometer. The obtained data indicated that the cutaneous temperature recorded by the infrared thermometers was not in agreement with the data recorded by the digital thermometer in the rectum. In cats, the use of non-contact infrared thermometers gave no reproducible or constant data to justify their application for the recording of body temperature instead of rectal temperature recording. In addition, the infrared temperature measurement devices generated results that were not in good agreement among themselves, providing a novel result of clinical importance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3234988
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 1
social impact