Introduction: After a failed percutaneous ultrasound (US)-guided sampling, it is recommended that endoscopic ultrasound (EUS)-guided tissue acquisition (TA) be performed for non-resectable solid pancreatic lesions according to the European Federation of Societies for Ultrasound in Medicine and Biology. However, the diagnostic performance of EUS-guided TA in this setting is unknown. Methods: We retrospectively analyzed the performance and safety of EUS-guided TA in patients with a previous failed percutaneous biopsy. We also evaluated the diagnostic delays between the percutaneous approach and EUS diagnosis. Results: Over a period of 2 years, 49 patients were identified (29 males, mean age 65 years). The reasons for failure of percutaneous sampling were inadequate samples in 25 (52.1%) cases and lesions that were not visible or targetable in 24 (47.9%) cases. In one case, EUS-guided TA was not performed because of the interposition of a metallic biliary stent. No adverse events were recorded for both the percutaneous and EUS approaches. The median diagnostic delay was 12 days. Overall, the sensitivity and accuracy of EUS-guided TA were 92.7 and 93.7%, respectively. A subgroup analysis examined cases with inadequate samples obtained with the percutaneous approach, and the sensitivity and accuracy of EUS-guided TA were 85.7 and 88%, respectively. Conclusion: EUS-guided TA is safe and accurate for the diagnosis of pancreatic lesions after a previous inconclusive percutaneous approach.

Diagnostic yield of endoscopic ultrasound-guided tissue acquisition of solid pancreatic lesions after inconclusive percutaneous ultrasound-guided tissue acquisition

Pallio S.;Crino S. F.
2020-01-01

Abstract

Introduction: After a failed percutaneous ultrasound (US)-guided sampling, it is recommended that endoscopic ultrasound (EUS)-guided tissue acquisition (TA) be performed for non-resectable solid pancreatic lesions according to the European Federation of Societies for Ultrasound in Medicine and Biology. However, the diagnostic performance of EUS-guided TA in this setting is unknown. Methods: We retrospectively analyzed the performance and safety of EUS-guided TA in patients with a previous failed percutaneous biopsy. We also evaluated the diagnostic delays between the percutaneous approach and EUS diagnosis. Results: Over a period of 2 years, 49 patients were identified (29 males, mean age 65 years). The reasons for failure of percutaneous sampling were inadequate samples in 25 (52.1%) cases and lesions that were not visible or targetable in 24 (47.9%) cases. In one case, EUS-guided TA was not performed because of the interposition of a metallic biliary stent. No adverse events were recorded for both the percutaneous and EUS approaches. The median diagnostic delay was 12 days. Overall, the sensitivity and accuracy of EUS-guided TA were 92.7 and 93.7%, respectively. A subgroup analysis examined cases with inadequate samples obtained with the percutaneous approach, and the sensitivity and accuracy of EUS-guided TA were 85.7 and 88%, respectively. Conclusion: EUS-guided TA is safe and accurate for the diagnosis of pancreatic lesions after a previous inconclusive percutaneous approach.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3247526
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact