The use of telerehabilitation systems has shown a significant growth in the past years, demonstrating their crucial relevance in the time of the COVID-19 pandemic. Many devices and sensors have been proposed to analytically measure parameters for patient assessment, with limitations due to costs or feasibility. In this paper, we present a motor telerehabilitation system with computer vision-assisted markerless measures for patients with Rett syndrome. Twenty-one RTT (Rett syndrome) patients, with ages ranging from age 4 to 31 (Median: 12.50; IQR (interquartile range): 9.50–17.25) were recruited. The study follows a pre-test–post-test design, where the patients were submitted to a pre-test, treatment, post-test 1, treatment, post-test 2 procedure. Progress in patient outcomes was assessed by measuring joint passive range of movement (PRoM). Results show the reliability of our system, and the feasibility of a telerehabilitation treatment for RTT patients, with significant improvements in shoulder mobility and in elbow flexion and extension. Limited results in lower limbs suggest that home treatment should be fostered to reduce sedentary time.

Telerehabilitation with Computer Vision-Assisted Markerless Measures: A Pilot Study with Rett Syndrome Patients

Nucita, Andrea
Primo
;
Iannizzotto, Giancarlo;Fabio, Rosa Angela
Ultimo
2023-01-01

Abstract

The use of telerehabilitation systems has shown a significant growth in the past years, demonstrating their crucial relevance in the time of the COVID-19 pandemic. Many devices and sensors have been proposed to analytically measure parameters for patient assessment, with limitations due to costs or feasibility. In this paper, we present a motor telerehabilitation system with computer vision-assisted markerless measures for patients with Rett syndrome. Twenty-one RTT (Rett syndrome) patients, with ages ranging from age 4 to 31 (Median: 12.50; IQR (interquartile range): 9.50–17.25) were recruited. The study follows a pre-test–post-test design, where the patients were submitted to a pre-test, treatment, post-test 1, treatment, post-test 2 procedure. Progress in patient outcomes was assessed by measuring joint passive range of movement (PRoM). Results show the reliability of our system, and the feasibility of a telerehabilitation treatment for RTT patients, with significant improvements in shoulder mobility and in elbow flexion and extension. Limited results in lower limbs suggest that home treatment should be fostered to reduce sedentary time.
2023
File in questo prodotto:
File Dimensione Formato  
2023-2 Skeleton Rett electronics-12-00435.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.96 MB
Formato Adobe PDF
1.96 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3248661
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact