In-stent restenosis (ISR) is a common superficial femoral artery (SFA) stenting complication, occurring in more than one third of patients within 2-3 years after the index procedure. Moreover, there is no standard treatment for ISR, and although many options are available, there is still limited data regarding its optimal management. We report a paradigmatic case report of a patient complaining of symptomatic peripheral arterial disease, underwent multiple endovascular revascularizations for recurrent femoro-popliteal ISR. A step-by-step approach was followed. At the time of the first presentation, the ISR was treated by drug-eluting balloon (DEB) angioplasty. The repeated ISR was treated by laser debulking, achieving a good angiographic result. Finally, after the third repeated restenosis, a combined approach with laser debulking and DEB angioplasty guaranteed a good acute angiographic result. Long-term duplex-scan follow-up demonstrated the good patency of the femoro-popliteal target lesion.

In-stent restenosis of superficial femoral artery: use all arrows in the quiver

Costa, Francesco;Bottari, Antonio;Patanè, Francesco;Micari, Antonio
2022-01-01

Abstract

In-stent restenosis (ISR) is a common superficial femoral artery (SFA) stenting complication, occurring in more than one third of patients within 2-3 years after the index procedure. Moreover, there is no standard treatment for ISR, and although many options are available, there is still limited data regarding its optimal management. We report a paradigmatic case report of a patient complaining of symptomatic peripheral arterial disease, underwent multiple endovascular revascularizations for recurrent femoro-popliteal ISR. A step-by-step approach was followed. At the time of the first presentation, the ISR was treated by drug-eluting balloon (DEB) angioplasty. The repeated ISR was treated by laser debulking, achieving a good angiographic result. Finally, after the third repeated restenosis, a combined approach with laser debulking and DEB angioplasty guaranteed a good acute angiographic result. Long-term duplex-scan follow-up demonstrated the good patency of the femoro-popliteal target lesion.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3250065
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact