BACKGROUND AND AIMS: Although endoscopic ultrasound (EUS) is generally safe, duodenal perforation may occur during the procedure. When the iatrogenic break is wide, endoscopic positioning of a covered self- expandable metal stent is indicated to avoid a more invasive surgical approach. We evaluated the efficacy of the 'over-the-scope stenting' (OTSS) technique to treat iatrogenic duodenal perforations occurred during EUS. METHODS: Data of patients with large iatrogenic duodenal perforations treated with OTSS procedure were collected in 5 centers. Technical success was defined as a correct stent placement on the perforation site, and clinical success as complete healing of the duodenal leak at stent removal 3 weeks later. RESULTS: A total of 15 (7 males; median age: 78 years, range 47-91) patients were included in this series. A correct stent positioning was achieved in all cases (technical success: 100%), and the perforation was healed in all, apart from one patient at stent removal (clinical success: 93%). This patient was successfully treated with a novel stent placement. No immediate post-procedural adverse events occurred, and no need for emergency surgery was recorded. In one (6.7%) patient, stent migration occurred 10 days after positioning, and it was spontaneously expulsed with stool movement without complications two days later. CONCLUSIONS: Our data showed that the OTTS technique for partially covered self-expandable metal stent placement is feasible, safe and effective to tread large iatrogenic duodenal perforation occuring during EUS.

Over-the-scope Technique for Partially Covered Self-expandable Metal Stent Placement to Treat Duodenal Perforation during EUS

Pallio S.;
2023-01-01

Abstract

BACKGROUND AND AIMS: Although endoscopic ultrasound (EUS) is generally safe, duodenal perforation may occur during the procedure. When the iatrogenic break is wide, endoscopic positioning of a covered self- expandable metal stent is indicated to avoid a more invasive surgical approach. We evaluated the efficacy of the 'over-the-scope stenting' (OTSS) technique to treat iatrogenic duodenal perforations occurred during EUS. METHODS: Data of patients with large iatrogenic duodenal perforations treated with OTSS procedure were collected in 5 centers. Technical success was defined as a correct stent placement on the perforation site, and clinical success as complete healing of the duodenal leak at stent removal 3 weeks later. RESULTS: A total of 15 (7 males; median age: 78 years, range 47-91) patients were included in this series. A correct stent positioning was achieved in all cases (technical success: 100%), and the perforation was healed in all, apart from one patient at stent removal (clinical success: 93%). This patient was successfully treated with a novel stent placement. No immediate post-procedural adverse events occurred, and no need for emergency surgery was recorded. In one (6.7%) patient, stent migration occurred 10 days after positioning, and it was spontaneously expulsed with stool movement without complications two days later. CONCLUSIONS: Our data showed that the OTTS technique for partially covered self-expandable metal stent placement is feasible, safe and effective to tread large iatrogenic duodenal perforation occuring during EUS.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3256456
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact