Barium inhalation usually relates to accidental aspiration during radiological procedures with an oral contrast agent. When present, barium lung deposits are visible as high-density opacities on chest X-ray or CT scan due to high atomic number, and they may be indistinguishable from calcifications. Dual-layer spectral CT has shown good material differentiation capabilities, due to its increased high-Z element range and smaller spectral separation between low- and high-energy spectral data. We present the case of a 17-year-old female with a history of tracheoesophageal fistula, who underwent chest CT angiography on a dual-layer spectral platform. Despite the close Z numbers and K-edge energy levels of the two different contrast materials, spectral CT was able to identify barium lung deposits from a previous swallowing study and to clearly distinguish them from calcium and the surrounding iodine-containing structures.

Multi-Contrast Differentiation by Dual-Energy Spectral CT Angiography in a Patient with Pulmonary Barium Granulomas

D'Angelo, Tommaso
Primo
;
Arico, Francesco
Secondo
;
Broccio, Lydia;Ascenti, Giorgio;Mazziotti, Silvio;Lanzafame, Ludovica;Blandino, Alfredo
Penultimo
;
Sofia, Carmelo
Ultimo
2023-01-01

Abstract

Barium inhalation usually relates to accidental aspiration during radiological procedures with an oral contrast agent. When present, barium lung deposits are visible as high-density opacities on chest X-ray or CT scan due to high atomic number, and they may be indistinguishable from calcifications. Dual-layer spectral CT has shown good material differentiation capabilities, due to its increased high-Z element range and smaller spectral separation between low- and high-energy spectral data. We present the case of a 17-year-old female with a history of tracheoesophageal fistula, who underwent chest CT angiography on a dual-layer spectral platform. Despite the close Z numbers and K-edge energy levels of the two different contrast materials, spectral CT was able to identify barium lung deposits from a previous swallowing study and to clearly distinguish them from calcium and the surrounding iodine-containing structures.
2023
Inglese
ELETTRONICO
Si
No
No
No
0
Euro
MDPI
13
5
832
838
7
https://www.mdpi.com/2075-4418/13/5/832
Internazionale
Esperti anonimi
aspiration; barium; computed tomography angiography; contrast media; pneumonia; respiratory tract fistula
info:eu-repo/semantics/article
D'Angelo, Tommaso; Arico, Francesco; Broccio, Lydia; Ascenti, Giorgio; Mazziotti, Silvio; Booz, Christian; Martin, Simon S; Yel, Ibrahim; Lanzafame, L...espandi
14.a Contributo in Rivista::14.a.1 Articolo su rivista
11
262
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3258248
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact