The purpose of this study was to compare the visual performance and optical quality between three new enhanced monofocal intraocular lenses (IOLs). This retrospective study included patients affected by cataracts with corneal astigmatism less than 0.75 D and no ocular comorbidities who underwent cataract surgery with bilateral implantation of Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc., Jacksonville, FL, USA), Vivinex Impress XY1-EM (Hoya Surgical Optics, Singapore) or IsoPure 123 (PhysIOL, Liege, Belgium) IOLs. Three months postoperatively, monocular and binocular uncorrected and corrected distant, and intermediate and near visual acuities were measured. Binocular defocus curve, photopic contrast sensitivity, Point Spread Function (PSF), low order aberrations (LOAs), high order aberrations (HOAs), objective scatter index (OSI), halo and glare perception were also evaluated. This study included a total of 72 eyes from 36 patients. Visual acuity outcomes, PSF, LOAs, HOAs and OSI were similar between groups. There were no statistically significant differences in terms of photopic contrast sensitivity, halo or glare perception. In patients without ocular comorbidities, the Eyhance ICB00 IOL, the Vivinex Impress IOL and the Isopure IOL-even though based on different optical properties-provided similar results in terms of visual acuity, contrast sensitivity and intraocular aberrations, with no influence on photic phenomena.

Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models

Roszkowska, Anna Maria;
2023-01-01

Abstract

The purpose of this study was to compare the visual performance and optical quality between three new enhanced monofocal intraocular lenses (IOLs). This retrospective study included patients affected by cataracts with corneal astigmatism less than 0.75 D and no ocular comorbidities who underwent cataract surgery with bilateral implantation of Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc., Jacksonville, FL, USA), Vivinex Impress XY1-EM (Hoya Surgical Optics, Singapore) or IsoPure 123 (PhysIOL, Liege, Belgium) IOLs. Three months postoperatively, monocular and binocular uncorrected and corrected distant, and intermediate and near visual acuities were measured. Binocular defocus curve, photopic contrast sensitivity, Point Spread Function (PSF), low order aberrations (LOAs), high order aberrations (HOAs), objective scatter index (OSI), halo and glare perception were also evaluated. This study included a total of 72 eyes from 36 patients. Visual acuity outcomes, PSF, LOAs, HOAs and OSI were similar between groups. There were no statistically significant differences in terms of photopic contrast sensitivity, halo or glare perception. In patients without ocular comorbidities, the Eyhance ICB00 IOL, the Vivinex Impress IOL and the Isopure IOL-even though based on different optical properties-provided similar results in terms of visual acuity, contrast sensitivity and intraocular aberrations, with no influence on photic phenomena.
2023
File in questo prodotto:
File Dimensione Formato  
jcm-12-03588 IOLS Rita.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 794.81 kB
Formato Adobe PDF
794.81 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3259466
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact