AimThe aim of the present study was to propose the clinical efficacy of the different dentin matrix obtained from three devices (BonMaker, Tooth Transformer, and Smart Dentin Grinder) and to show their morphological, physical, and biochemical characteristics using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) spectroscopy, and Raman spectroscopy.Research design and methodsThe study included 70 patients who underwent bone augmentation using the BonMaker, Tooth Transformer, and Smart Dentin Grinder devices. In addition, 84 implants were placed. Furthermore, four samples, one for each device and one non-demineralized control, were analyzed with scanning electron microscopy (SEM), energy-dispersive X-ray analysis, and Raman spectroscopy.ResultsIn all patients, augmentation of bone defects with ground dentin matrix was successful, and implants showed correct osseointegration. The morphological organization, the chemical composition, and the presence of organic molecules in the dentin samples processed by the three different devices were demonstrated using SEM, energy-dispersive X-ray analysis, and Raman spectroscopy.ConclusionsComparing BonMaker, Tooth Transformer, and Smart Dentin Grinder devices in our practice, we concluded that these systems, even with different structural and chemical differences of the dentin granules, have a comparable potential for obtaining regenerative material from the patient's own teeth.

Comparison of clinical efficacy of three different dentin matrix biomaterials obtained from different devices

Puzzolo, Domenico;Santoro, Giuseppe;Micali, Antonio;Testagrossa, Barbara;Acri, Giuseppe
2023-01-01

Abstract

AimThe aim of the present study was to propose the clinical efficacy of the different dentin matrix obtained from three devices (BonMaker, Tooth Transformer, and Smart Dentin Grinder) and to show their morphological, physical, and biochemical characteristics using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) spectroscopy, and Raman spectroscopy.Research design and methodsThe study included 70 patients who underwent bone augmentation using the BonMaker, Tooth Transformer, and Smart Dentin Grinder devices. In addition, 84 implants were placed. Furthermore, four samples, one for each device and one non-demineralized control, were analyzed with scanning electron microscopy (SEM), energy-dispersive X-ray analysis, and Raman spectroscopy.ResultsIn all patients, augmentation of bone defects with ground dentin matrix was successful, and implants showed correct osseointegration. The morphological organization, the chemical composition, and the presence of organic molecules in the dentin samples processed by the three different devices were demonstrated using SEM, energy-dispersive X-ray analysis, and Raman spectroscopy.ConclusionsComparing BonMaker, Tooth Transformer, and Smart Dentin Grinder devices in our practice, we concluded that these systems, even with different structural and chemical differences of the dentin granules, have a comparable potential for obtaining regenerative material from the patient's own teeth.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3262888
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact