: Complications after device closure of ostium secundum defects are rare but possible. We present a very late erosion of the interatrial septum after a percutaneous closure of an ostium secundum defect. Identification of early clinical and imaging clues associated with this condition is fundamental for a timely diagnosis and treatment. (Level of Difficulty: Intermediate.).

A Very Late Atrial Septal Erosion After an Ostium Secundum Percutaneous Closure

Lofrumento, Francesca
Primo
;
Costa, Francesco;Perfetti, Silvia;Di Bella, Gianluca;Zito, Concetta;Carerj, Scipione;Micari, Antonio
Ultimo
2023-01-01

Abstract

: Complications after device closure of ostium secundum defects are rare but possible. We present a very late erosion of the interatrial septum after a percutaneous closure of an ostium secundum defect. Identification of early clinical and imaging clues associated with this condition is fundamental for a timely diagnosis and treatment. (Level of Difficulty: Intermediate.).