Patients with diabetes mellitus (DM) are at higher risk of restenosis and stent thrombosis after percutaneous coronary intervention (PCI) and drug-eluting stent (DES) positioning. Whether drug-coated balloons (DCB) can offer any benefit in this subset of patients has been seldom cleared out and was the aim of the present propensity-matched cohort study, that compared the prognostic impact of DCB versus DES in patients with DM who underwere identified and matched according to propensity score, to a control population of patients with DM treated with DES. The primary study end point was the occurrence of major adverse cardiovascular events (MACEs). A total of 150 patients were identified in the DCB group and matched with 150 DES-treated patients. Patients treated with DCB displayed more often a previous cardiovascular history and received a more complete pharmacological therapy. Target vessel diameter and the percentage of stenosis were lower in patients with DCB, whereas binary in-stent restenosis was more common (p <0.001, p = 0.003, and p <0.001, respectively). Paclitaxel-eluting balloon represented the most common strategy in the DCB group, whereas Zotarolimus-eluting stents were used in half of the DES population. At a median follow-up of 545.5 days, MACE occurred in 54 (19.4%) of patients, with no difference according to the PCI strategy (21.6% vs 17.3%, adjusted hazard ratio [95% confidence interval] 1.51 [0.46 to 4.93], p = 0.50). Major ischemic end points were slightly increased in patients treated with DCB, whereas overall death was significantly reduced (3.6% vs 10.9%; adjusted hazard ratio [95% confidence interval] 0.27 [0.08 to 0.91], p = 0.03).In conclusion, the present propensity-matched study shows that, in patients with DM who underwent PCI for in-stent restenosis or de novo lesions, the use of DCB is associated with a similar rate of MACE and a modest increase in target lesion failure, but a significantly improved survival as compared with DES. (c) 2023 Elsevier Inc. All rights reserved.

Prognostic Impact of Drug-Coated Balloons in Patients With Diabetes Mellitus: A Propensity-Matched Study

De Luca, Giuseppe
Ultimo
Supervision
2023-01-01

Abstract

Patients with diabetes mellitus (DM) are at higher risk of restenosis and stent thrombosis after percutaneous coronary intervention (PCI) and drug-eluting stent (DES) positioning. Whether drug-coated balloons (DCB) can offer any benefit in this subset of patients has been seldom cleared out and was the aim of the present propensity-matched cohort study, that compared the prognostic impact of DCB versus DES in patients with DM who underwere identified and matched according to propensity score, to a control population of patients with DM treated with DES. The primary study end point was the occurrence of major adverse cardiovascular events (MACEs). A total of 150 patients were identified in the DCB group and matched with 150 DES-treated patients. Patients treated with DCB displayed more often a previous cardiovascular history and received a more complete pharmacological therapy. Target vessel diameter and the percentage of stenosis were lower in patients with DCB, whereas binary in-stent restenosis was more common (p <0.001, p = 0.003, and p <0.001, respectively). Paclitaxel-eluting balloon represented the most common strategy in the DCB group, whereas Zotarolimus-eluting stents were used in half of the DES population. At a median follow-up of 545.5 days, MACE occurred in 54 (19.4%) of patients, with no difference according to the PCI strategy (21.6% vs 17.3%, adjusted hazard ratio [95% confidence interval] 1.51 [0.46 to 4.93], p = 0.50). Major ischemic end points were slightly increased in patients treated with DCB, whereas overall death was significantly reduced (3.6% vs 10.9%; adjusted hazard ratio [95% confidence interval] 0.27 [0.08 to 0.91], p = 0.03).In conclusion, the present propensity-matched study shows that, in patients with DM who underwent PCI for in-stent restenosis or de novo lesions, the use of DCB is associated with a similar rate of MACE and a modest increase in target lesion failure, but a significantly improved survival as compared with DES. (c) 2023 Elsevier Inc. All rights reserved.
2023
Inglese
Inglese
STAMPA
EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC
206
73
78
6
Internazionale
Esperti anonimi
diabetes mellitus; drug-coated balloon; drug-eluting stent; outcomes; target lesion failure
info:eu-repo/semantics/article
Verdoia, Monica; Zilio, Filippo; Gioscia, Rocco; Viola, Orazio; Brancati, Marta Francesca; Fanti, Diego; Soldà, Pier Luigi; Bonmassari, Roberto; Rogno...espandi
14.a Contributo in Rivista::14.a.1 Articolo su rivista
10
262
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3286009
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact