Background: Advances in diabetes technological devices led to optimization of diabetes care; however, long-lasting skin exposure to devices may be accompanied by an increasing occurrence of cutaneous reactions. Methods: We used an open-link web-based survey to evaluate diabetes-care providers' viewpoint on prevalence, management practices, and knowledge related to skin reactions with the use of diabetes technological devices. A post hoc analysis was applied to investigate differences in the level of awareness on this topic in relation to the experience in diabetes technology. Results: One hundred twenty-five responses from 39 different countries were collected. Most respondents (69%) routinely examine patients' skin at each visit. All the preventive measures are not clear and, mainly, homogenously put into clinical practice. Contact dermatitis was the most frequently reported cutaneous complication due to diabetes devices, and its most common provocative causes are not yet fully known by diabetes-care providers. Almost half of the respondents (42%) had discussed the presence of harmful allergens contained in adhesives with device manufacturers. There is general agreement on the need to strengthen knowledge on dermatological complications. Conclusions: Although diabetes-care providers are quite aware of the chance to develop skin reactions in people with diabetes using technological devices, there are still some unmet needs. Large follow-up studies and further dissemination tools are awaited to address the gaps revealed by our survey.

First International Survey on Diabetes Providers’ Assessment of Skin Reactions in Youth With Type 1 Diabetes Using Technological Devices

Passanisi, Stefano
Primo
Writing – Original Draft Preparation
;
Lombardo, Fortunato
Ultimo
Writing – Review & Editing
;
2023-01-01

Abstract

Background: Advances in diabetes technological devices led to optimization of diabetes care; however, long-lasting skin exposure to devices may be accompanied by an increasing occurrence of cutaneous reactions. Methods: We used an open-link web-based survey to evaluate diabetes-care providers' viewpoint on prevalence, management practices, and knowledge related to skin reactions with the use of diabetes technological devices. A post hoc analysis was applied to investigate differences in the level of awareness on this topic in relation to the experience in diabetes technology. Results: One hundred twenty-five responses from 39 different countries were collected. Most respondents (69%) routinely examine patients' skin at each visit. All the preventive measures are not clear and, mainly, homogenously put into clinical practice. Contact dermatitis was the most frequently reported cutaneous complication due to diabetes devices, and its most common provocative causes are not yet fully known by diabetes-care providers. Almost half of the respondents (42%) had discussed the presence of harmful allergens contained in adhesives with device manufacturers. There is general agreement on the need to strengthen knowledge on dermatological complications. Conclusions: Although diabetes-care providers are quite aware of the chance to develop skin reactions in people with diabetes using technological devices, there are still some unmet needs. Large follow-up studies and further dissemination tools are awaited to address the gaps revealed by our survey.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3287917
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact