Background: Scarce data are available on the long-term outcomes of different regimens of oral anticoagulation in an all comer population of patients undergoing aortic valve replacement with a bileaflet mechanical heart valve.Methods: Outcomes of 88 patients discharged with a target INR of 2.0 (LOW-INR) were compared to 147 contemporary patients who have been recommended a target INR of 2.5 (CONV). Primary outcome was the composite of any thromboembolic or haemorrhagic events. Secondary outcomes were the individual components of the primary outcome, cardiovascular mortality and stroke. To reduce selection bias, a propensity weighted analysis was performed.Results: After inverse probability of treatment weighting, the primary endpoint occurred in 0.7% of patient in the LOW-INR group and in 7.0% in the CONV group (p = .0255). Linearized event rate were significantly lower in the LOW-INR group (primary endpoint: rate difference - 12.0 per 1000 patient/years, p = .0052; haemorrhage: -5.8 per 1000 patient/years, p = .0330; neurological events: -7.6 per 1000 patient/years, p = .0140). Conventional target INR was associated with an increased hazard of the composite endpoint (HR 11.193, 95% CI 1.424-88.003, p = .0217).Conclusions: Lowering the intensity of oral anticoagulation resulted in a relevant clinical benefit of reduced rates of haemorrhagic and neurological adverse events in the mid-term follow-up. This report confirms the safety profile of the low INR regimen in an all comer population undergoing aortic valve replacement with an Abbott mechanical valve. (c) 2020 Elsevier B.V. All rights reserved.

Safety of low intensity oral anticoagulant therapy in patients with bileaflet mechanical aortic valve prosthesis: A propensity weighted study

Rubino, Antonino S.
Primo
Writing – Original Draft Preparation
;
2020-01-01

Abstract

Background: Scarce data are available on the long-term outcomes of different regimens of oral anticoagulation in an all comer population of patients undergoing aortic valve replacement with a bileaflet mechanical heart valve.Methods: Outcomes of 88 patients discharged with a target INR of 2.0 (LOW-INR) were compared to 147 contemporary patients who have been recommended a target INR of 2.5 (CONV). Primary outcome was the composite of any thromboembolic or haemorrhagic events. Secondary outcomes were the individual components of the primary outcome, cardiovascular mortality and stroke. To reduce selection bias, a propensity weighted analysis was performed.Results: After inverse probability of treatment weighting, the primary endpoint occurred in 0.7% of patient in the LOW-INR group and in 7.0% in the CONV group (p = .0255). Linearized event rate were significantly lower in the LOW-INR group (primary endpoint: rate difference - 12.0 per 1000 patient/years, p = .0052; haemorrhage: -5.8 per 1000 patient/years, p = .0330; neurological events: -7.6 per 1000 patient/years, p = .0140). Conventional target INR was associated with an increased hazard of the composite endpoint (HR 11.193, 95% CI 1.424-88.003, p = .0217).Conclusions: Lowering the intensity of oral anticoagulation resulted in a relevant clinical benefit of reduced rates of haemorrhagic and neurological adverse events in the mid-term follow-up. This report confirms the safety profile of the low INR regimen in an all comer population undergoing aortic valve replacement with an Abbott mechanical valve. (c) 2020 Elsevier B.V. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3296559
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact