In this work, the development of a graphene quantum dots (GQDs)-modified screen-printed carbon (SPCE) electrode for the determination of cannabidiol (CBD), a cannabinoid present in the Cannabis L. Sativa (hemp) plant, is reported. This cannabinoid is non-intoxicating and non-psychoactive, thus CBD-containing drugs as well as CBD-containing foods, are now on the market in many countries due to their health-beneficial effects and pharmacological activities. Because of the increasing interest in analyzing CBD in these real samples, we analyzed here a sample of hemp flour that was used for testing the developed CBD electrochemical sensor. Preliminary work devoted to optimizing the analysis conditions, allowed to development of a GQDs-modified electrode with promising characteristics for the simple screening of CBD. The electroanalytical tests for CBD detection showed a sensitivity of 0.98 μAμM-1 cm−2, which is increased by 2-folder compared to bare SPCE, and a limit of detection (LOD) equal to 0.277 μM. The developed GQDs/SPCE sensor and the analysis procedure were then applied for the CBD analysis in a hemp seeds flour sample. Based on the results obtained, the advantages/disadvantages evidenced by operating with the developed electrochemical sensor in the analysis of CBD in real samples were discussed.

Graphene quantum dots (GQDs)-modified screen-printed electrode for the determination of cannabidiol (CBD) in hemp seeds flour

Abid K.;Neri G.
2024-01-01

Abstract

In this work, the development of a graphene quantum dots (GQDs)-modified screen-printed carbon (SPCE) electrode for the determination of cannabidiol (CBD), a cannabinoid present in the Cannabis L. Sativa (hemp) plant, is reported. This cannabinoid is non-intoxicating and non-psychoactive, thus CBD-containing drugs as well as CBD-containing foods, are now on the market in many countries due to their health-beneficial effects and pharmacological activities. Because of the increasing interest in analyzing CBD in these real samples, we analyzed here a sample of hemp flour that was used for testing the developed CBD electrochemical sensor. Preliminary work devoted to optimizing the analysis conditions, allowed to development of a GQDs-modified electrode with promising characteristics for the simple screening of CBD. The electroanalytical tests for CBD detection showed a sensitivity of 0.98 μAμM-1 cm−2, which is increased by 2-folder compared to bare SPCE, and a limit of detection (LOD) equal to 0.277 μM. The developed GQDs/SPCE sensor and the analysis procedure were then applied for the CBD analysis in a hemp seeds flour sample. Based on the results obtained, the advantages/disadvantages evidenced by operating with the developed electrochemical sensor in the analysis of CBD in real samples were discussed.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3312669
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact