Continuous glucose monitoring (CGM) systems, including real-time CGM and intermittently scanned CGM, have revolutionized diabetes management, particularly in children and adolescents with type 1 diabetes (T1D). These systems provide detailed insights into glucose variability and detect asymptomatic and nocturnal hypoglycemia, addressing limitations of traditional self-monitoring blood glucose methods. CGM devices measure interstitial glucose concentrations constantly, enabling proactive therapeutic decisions and optimization of glycemic control through stored data analysis. CGM metrics such as time in range, time below range, and coefficient of variation are crucial for managing T1D, with emerging metrics like time in tight range and glycemia risk index showing potential for enhanced glycemic assessment. Recent advancements suggest the utility of CGM systems in monitoring the early stages of T1D and individuals with obesity complicated by pre-diabetes, highlighting its therapeutic versatility. This review discusses the current CGM systems for T1D during the pediatric age, established and emerging metrics, and future applications, emphasizing the critical role of CGM devices in improving glycemic control and clinical outcomes in children and adolescents with diabetes.

Exploring the Continuous Glucose Monitoring in Pediatric Diabetes: Current Practices, Innovative Metrics, and Future Implications

Bombaci, Bruno
Writing – Original Draft Preparation
;
Passanisi, Stefano
Ultimo
Supervision
2024-01-01

Abstract

Continuous glucose monitoring (CGM) systems, including real-time CGM and intermittently scanned CGM, have revolutionized diabetes management, particularly in children and adolescents with type 1 diabetes (T1D). These systems provide detailed insights into glucose variability and detect asymptomatic and nocturnal hypoglycemia, addressing limitations of traditional self-monitoring blood glucose methods. CGM devices measure interstitial glucose concentrations constantly, enabling proactive therapeutic decisions and optimization of glycemic control through stored data analysis. CGM metrics such as time in range, time below range, and coefficient of variation are crucial for managing T1D, with emerging metrics like time in tight range and glycemia risk index showing potential for enhanced glycemic assessment. Recent advancements suggest the utility of CGM systems in monitoring the early stages of T1D and individuals with obesity complicated by pre-diabetes, highlighting its therapeutic versatility. This review discusses the current CGM systems for T1D during the pediatric age, established and emerging metrics, and future applications, emphasizing the critical role of CGM devices in improving glycemic control and clinical outcomes in children and adolescents with diabetes.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3315773
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact