Aim: Hostile aortic neck anatomy—characterized by short neck length, severe angulation, conical shape, and mural thrombus or calcifications—represents a major limitation to the durability and applicability of standard endovascular aneurysm repair (EVAR). In response to these challenges, newer endografts with improved conformability have been developed. This study aimed to evaluate the mid-term outcomes of EVAR using the GORE EXCLUDER Conformable AAA Endoprosthesis (CEXC) (W.L. Gore & Associates Inc., Flagstaff, AZ, USA) in patients with hostile neck anatomy, with specific attention to type III endoleak occurrence, aortic sac remodeling, and maintenance of distal sealing. Methods: A retrospective observational analysis was conducted on 50 consecutive patients treated with the CEXC endograft between October 2019 and September 2023. Patients included had either elective or urgent indications for EVAR and were evaluated preoperatively using CT angiography. Hostile neck criteria were defined according to the 2019 Delphi Consensus. Procedural variables, imaging follow-up, and clinical outcomes were collected. The primary endpoints were technical and clinical success, while secondary outcomes included endoleak rates, aneurysm sac evolution, and reintervention-free survival. Results: Technical success was achieved in 100% of cases, with a clinical success rate of 98%. No type Ia, Ib, or III endoleaks were observed at a median follow-up of 23 months. Sac shrinkage (>5 mm reduction) occurred in 70% of patients, and distal sealing was preserved in 100% of cases. One perioperative death occurred in an emergency setting, and no late reinterventions or aneurysm-related mortalities were reported. The use of intravascular ultrasound (IVUS) and floppy guidewires contributed to precise deployment and sealing in angulated anatomies. Conclusions: The CEXC endograft proved to be a safe and effective option for EVAR in patients with hostile aortic anatomy, ensuring durable proximal and distal sealing, promoting favorable sac remodeling, and preventing type III endoleaks. These findings support the use of CEXC in anatomically complex settings, as long as procedures are meticulously planned and guided by appropriate intraoperative imaging and deployment techniques.

Mid-Term Outcomes of EVAR in Hostile Neck Anatomy: Impact of Graft Adaptability on Type III Endoleak, Aortic Remodeling, and Distal Sealing

Fittipaldi, Alessandra;De Caridi, Giovanni;Benedetto, Filippo
2025-01-01

Abstract

Aim: Hostile aortic neck anatomy—characterized by short neck length, severe angulation, conical shape, and mural thrombus or calcifications—represents a major limitation to the durability and applicability of standard endovascular aneurysm repair (EVAR). In response to these challenges, newer endografts with improved conformability have been developed. This study aimed to evaluate the mid-term outcomes of EVAR using the GORE EXCLUDER Conformable AAA Endoprosthesis (CEXC) (W.L. Gore & Associates Inc., Flagstaff, AZ, USA) in patients with hostile neck anatomy, with specific attention to type III endoleak occurrence, aortic sac remodeling, and maintenance of distal sealing. Methods: A retrospective observational analysis was conducted on 50 consecutive patients treated with the CEXC endograft between October 2019 and September 2023. Patients included had either elective or urgent indications for EVAR and were evaluated preoperatively using CT angiography. Hostile neck criteria were defined according to the 2019 Delphi Consensus. Procedural variables, imaging follow-up, and clinical outcomes were collected. The primary endpoints were technical and clinical success, while secondary outcomes included endoleak rates, aneurysm sac evolution, and reintervention-free survival. Results: Technical success was achieved in 100% of cases, with a clinical success rate of 98%. No type Ia, Ib, or III endoleaks were observed at a median follow-up of 23 months. Sac shrinkage (>5 mm reduction) occurred in 70% of patients, and distal sealing was preserved in 100% of cases. One perioperative death occurred in an emergency setting, and no late reinterventions or aneurysm-related mortalities were reported. The use of intravascular ultrasound (IVUS) and floppy guidewires contributed to precise deployment and sealing in angulated anatomies. Conclusions: The CEXC endograft proved to be a safe and effective option for EVAR in patients with hostile aortic anatomy, ensuring durable proximal and distal sealing, promoting favorable sac remodeling, and preventing type III endoleaks. These findings support the use of CEXC in anatomically complex settings, as long as procedures are meticulously planned and guided by appropriate intraoperative imaging and deployment techniques.
2025
Inglese
Inglese
Multidisciplinary Digital Publishing Institute (MDPI)
14
17
1
10
10
Internazionale
Nessuno
aortic remodeling; conformable endograft; distal sealing; endovascular aneurysm repair; hostile neck; type III endoleak
no
info:eu-repo/semantics/article
Fittipaldi, Alessandra; Barillà, Chiara; Pipitò, Narayana; Squillaci, Domenico; De Caridi, Giovanni; Benedetto, Filippo
14.a Contributo in Rivista::14.a.1 Articolo su rivista
6
262
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3344649
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact