High-performance hydrogen sulfide (H2S) sensors are mandatory for many industrial applications. However, the development of H2S sensors still remains a challenge for researchers. In this work, we report the study of a TiO2-based conductometric sensor for H2S monitoring at low concentrations. TiO2 samples were first synthesized using the sol-gel route, annealed at different temperatures (400 and 600 °C), and thoroughly characterized to evaluate their morphological and microstructural properties. Scanning electronic microscopy, Raman scattering, X-ray diffraction, and FTIR spectroscopy have demonstrated the formation of clusters of pure anatase in the TiO2 phase. Increasing the calcination temperature to 600 °C enhanced TiO2 crystallinity and particle size (from 11 nm to 51 nm), accompanied by the transition to the rutile phase and a slight decrease in band gap (3.31 eV for 400 °C to 3.26 eV for 600 °C). Sensing tests demonstrate that TiO2 annealed at 400 °C displays good performances (sensor response Ra/Rg of ~3.3 at 2.5 ppm and fast response/recovery of 8 and 23 s, respectively) for the detection of H2S at low concentrations in air.

Conductometric H2S Sensors Based on TiO2 Nanoparticles

Alaya Y.;Fazio E.;Corsaro C.;Neri G.
2024-01-01

Abstract

High-performance hydrogen sulfide (H2S) sensors are mandatory for many industrial applications. However, the development of H2S sensors still remains a challenge for researchers. In this work, we report the study of a TiO2-based conductometric sensor for H2S monitoring at low concentrations. TiO2 samples were first synthesized using the sol-gel route, annealed at different temperatures (400 and 600 °C), and thoroughly characterized to evaluate their morphological and microstructural properties. Scanning electronic microscopy, Raman scattering, X-ray diffraction, and FTIR spectroscopy have demonstrated the formation of clusters of pure anatase in the TiO2 phase. Increasing the calcination temperature to 600 °C enhanced TiO2 crystallinity and particle size (from 11 nm to 51 nm), accompanied by the transition to the rutile phase and a slight decrease in band gap (3.31 eV for 400 °C to 3.26 eV for 600 °C). Sensing tests demonstrate that TiO2 annealed at 400 °C displays good performances (sensor response Ra/Rg of ~3.3 at 2.5 ppm and fast response/recovery of 8 and 23 s, respectively) for the detection of H2S at low concentrations in air.
2024
Inglese
Inglese
Multidisciplinary Digital Publishing Institute (MDPI)
17
13
1
16
16
Internazionale
Esperti anonimi
H2S sensor; sol-gel; thermal treatment; TiO; 2; nanopowder
Article number: 3283
info:eu-repo/semantics/article
Alaya, Y.; Madani, M.; Bouguila, N.; El Mir, L.; Fazio, E.; Corsaro, C.; Neri, G.
14.a Contributo in Rivista::14.a.1 Articolo su rivista
7
262
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3352975
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 5
social impact