This work presents a novel screen-printed carbon electrochemical sensing platform based on the zirconium metal-organic framework UiO-67 for the detection and quantification of tyrosine (Tyr) in aqueous biologically relevant environments. The microporous structure, high surface area and water stability of UiO-67 make it suitable as an electrode modifier for electrochemical sensing. UiO-67-modified screen-printed carbon electrode (UiO-67/SPCE) sensors were developed, and their electrochemical characteristics were evaluated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Linear Sweep Voltammetry (LSV) measurements were carried out to assess the electroanalytical performance for the detection of Tyr, including sensitivity, selectivity, and detection limit. The UiO-67/SPCE displayed a dynamic range of 0.5-200 μM and a very low LOD of 0.17 μM. The UiO-67-based sensor effectively distinguishes the target analyte even in a complex biological matrix, such as diluted bovine serum, highlighting its potential for biomedical diagnostics and food safety applications.

UiO-67 modified screen-printed carbon electrodes for selective electrochemical determination of tyrosine in complex biological matrices

Govar M. Abdullah
;
Meryem Chelly;Sabrine Chelly;Nania G.;Fazio E.;Corsaro C.;Saija R.;Neri G.
;
2027-01-01

Abstract

This work presents a novel screen-printed carbon electrochemical sensing platform based on the zirconium metal-organic framework UiO-67 for the detection and quantification of tyrosine (Tyr) in aqueous biologically relevant environments. The microporous structure, high surface area and water stability of UiO-67 make it suitable as an electrode modifier for electrochemical sensing. UiO-67-modified screen-printed carbon electrode (UiO-67/SPCE) sensors were developed, and their electrochemical characteristics were evaluated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Linear Sweep Voltammetry (LSV) measurements were carried out to assess the electroanalytical performance for the detection of Tyr, including sensitivity, selectivity, and detection limit. The UiO-67/SPCE displayed a dynamic range of 0.5-200 μM and a very low LOD of 0.17 μM. The UiO-67-based sensor effectively distinguishes the target analyte even in a complex biological matrix, such as diluted bovine serum, highlighting its potential for biomedical diagnostics and food safety applications.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3364250
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact