Progressive neurodegenerative diseases are often associated with motor symptoms, among which tremor is one of the most debilitating manifestations, significantly compromising daily activities and quality of life. Continuous, non-invasive monitoring of tremor characteristics helps to assess disease progression and optimize treatment strategies. For this reason, wearable measurement systems can provide an objective and non-invasive means for the quantitative characterization and monitoring of tremor-related movements. This study addresses the development of a compact, low-power wearable board for real-time tremor monitoring based on the Nicla Sense ME embedded system. The proposed device performs on-board processing to extract spectral features of movement and wirelessly sends them via Bluetooth Low Energy to a remote host, enabling on-demand visualization or storage of tremor data. The measurement system was technically validated through a comparative experimental protocol based on the simultaneous acquisition of tremor signals using the proposed device and a commercial Shimmer3 IMU as the reference system. The comparison considered both the similarity of the measured spectrograms and the agreement in dominant-frequency estimation. Spectrogram correlation coefficients reached 0.85, with amplitude MAE and RMSE values as low as 0.07 m/s2 and 0.14 m/s2, respectively. For dominant-frequency estimation, Pearson correlation coefficients reached 0.99, with MAE and RMSE values as low as 0.17 Hz and 0.20 Hz. These results support the feasibility of the proposed architecture as a practical wearable solution for quantitative hand tremor monitoring.
A Stand-Alone Wearable Measurement System for Continuous Hand Tremor Monitoring
Arruzzoli L.Primo
;Gugliandolo G.;Latino M.;Crupi G.;De Marchis C.Penultimo
;Donato N.Ultimo
2026-01-01
Abstract
Progressive neurodegenerative diseases are often associated with motor symptoms, among which tremor is one of the most debilitating manifestations, significantly compromising daily activities and quality of life. Continuous, non-invasive monitoring of tremor characteristics helps to assess disease progression and optimize treatment strategies. For this reason, wearable measurement systems can provide an objective and non-invasive means for the quantitative characterization and monitoring of tremor-related movements. This study addresses the development of a compact, low-power wearable board for real-time tremor monitoring based on the Nicla Sense ME embedded system. The proposed device performs on-board processing to extract spectral features of movement and wirelessly sends them via Bluetooth Low Energy to a remote host, enabling on-demand visualization or storage of tremor data. The measurement system was technically validated through a comparative experimental protocol based on the simultaneous acquisition of tremor signals using the proposed device and a commercial Shimmer3 IMU as the reference system. The comparison considered both the similarity of the measured spectrograms and the agreement in dominant-frequency estimation. Spectrogram correlation coefficients reached 0.85, with amplitude MAE and RMSE values as low as 0.07 m/s2 and 0.14 m/s2, respectively. For dominant-frequency estimation, Pearson correlation coefficients reached 0.99, with MAE and RMSE values as low as 0.17 Hz and 0.20 Hz. These results support the feasibility of the proposed architecture as a practical wearable solution for quantitative hand tremor monitoring.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.