Progressive neurodegenerative diseases are often associated with motor symptoms, among which tremor is one of the most debilitating manifestations, significantly compromising daily activities and quality of life. Continuous, non-invasive monitoring of tremor characteristics helps to assess disease progression and optimize treatment strategies. For this reason, wearable measurement systems can provide an objective and non-invasive means for the quantitative characterization and monitoring of tremor-related movements. This study addresses the development of a compact, low-power wearable board for real-time tremor monitoring based on the Nicla Sense ME embedded system. The proposed device performs on-board processing to extract spectral features of movement and wirelessly sends them via Bluetooth Low Energy to a remote host, enabling on-demand visualization or storage of tremor data. The measurement system was technically validated through a comparative experimental protocol based on the simultaneous acquisition of tremor signals using the proposed device and a commercial Shimmer3 IMU as the reference system. The comparison considered both the similarity of the measured spectrograms and the agreement in dominant-frequency estimation. Spectrogram correlation coefficients reached 0.85, with amplitude MAE and RMSE values as low as 0.07 m/s2 and 0.14 m/s2, respectively. For dominant-frequency estimation, Pearson correlation coefficients reached 0.99, with MAE and RMSE values as low as 0.17 Hz and 0.20 Hz. These results support the feasibility of the proposed architecture as a practical wearable solution for quantitative hand tremor monitoring.

A Stand-Alone Wearable Measurement System for Continuous Hand Tremor Monitoring

Arruzzoli L.
Primo
;
Gugliandolo G.;Latino M.;Crupi G.;De Marchis C.
Penultimo
;
Donato N.
Ultimo
2026-01-01

Abstract

Progressive neurodegenerative diseases are often associated with motor symptoms, among which tremor is one of the most debilitating manifestations, significantly compromising daily activities and quality of life. Continuous, non-invasive monitoring of tremor characteristics helps to assess disease progression and optimize treatment strategies. For this reason, wearable measurement systems can provide an objective and non-invasive means for the quantitative characterization and monitoring of tremor-related movements. This study addresses the development of a compact, low-power wearable board for real-time tremor monitoring based on the Nicla Sense ME embedded system. The proposed device performs on-board processing to extract spectral features of movement and wirelessly sends them via Bluetooth Low Energy to a remote host, enabling on-demand visualization or storage of tremor data. The measurement system was technically validated through a comparative experimental protocol based on the simultaneous acquisition of tremor signals using the proposed device and a commercial Shimmer3 IMU as the reference system. The comparison considered both the similarity of the measured spectrograms and the agreement in dominant-frequency estimation. Spectrogram correlation coefficients reached 0.85, with amplitude MAE and RMSE values as low as 0.07 m/s2 and 0.14 m/s2, respectively. For dominant-frequency estimation, Pearson correlation coefficients reached 0.99, with MAE and RMSE values as low as 0.17 Hz and 0.20 Hz. These results support the feasibility of the proposed architecture as a practical wearable solution for quantitative hand tremor monitoring.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3364289
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact